Lucene search
+L

460 matches found

Tenable Nessus
Tenable Nessus
added 2023/07/31 12:00 a.m.107 views

NASL Plugin Signature Checks Disabled

This scan was executed with signature checking for Nessus plugins disabled by a scan setting. This permits plugins to run which have not been vetted by Tenable. Unless you have an extremely good reason for enabling this setting, it is recommended that you disable that setting. %NASLMINLEVEL 80900...

5.4AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2021/08/12 12:00 a.m.58 views

Ubuntu 18.04 LTS : OpenSSH regression (USN-3809-2)

The remote Ubuntu 18.04 LTS host has packages installed that are affected by a vulnerability as referenced in the USN-3809-2 advisory. USN-3809-1 fixed vulnerabilities in OpenSSH. The update for CVE-2018-15473 was incomplete and could introduce a regression in certain environments. This update...

5.9CVSS6.8AI score0.98631EPSS
SaveExploits26References1
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.19 views

Siemens Sicam Missing Authentication for Critical Function

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the device's web server might be able to execute administrative commands without authentication. File data ot500430.nasl...

7.5CVSS4AI score0.01235EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Schneider-electric Modicon Out-of-bounds Read

A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...

5.8CVSS4.6AI score0.00902EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.18 views

Siemens Simatic Uncaught Exception

A vulnerability has been identified in SIMATIC ET 200SP Open Controller incl. SIPLUS variants V20.8, SIMATIC S7-1500 Software Controller V20.8. The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a...

5CVSS1.9AI score0.01591EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.47 views

Saia_burgess_controls Pcd1.m0xx0 Unspecified Vulnerability

Saia Burgess PCD1.M0xx0, PCD1.M2xx0, PCD2.M5xx0, PCD3.Mxx60, PCD3.Mxxx0, PCD7.D4xxD, PCD7.D4xxV, PCD7.D4xxWTPF, and PCD7.D4xxxT5F devices before 1.24.50 and PCD3.T665 and PCD3.T666 devices before 1.24.41 have hardcoded credentials, which allows remote attackers to obtain administrative access via...

10CVSS6.3AI score0.02419EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.30 views

Emerson Deltav Unspecified Vulnerability

Emerson DeltaV 10.3.1, 11.3, 11.3.1, and 12.3 uses hardcoded credentials for diagnostic services, which allows remote attackers to bypass intended access restrictions via a TCP session, as demonstrated by a session that uses the telnet program. File data ot500421.nasl...

7.5CVSS5.3AI score0.01319EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.23 views

Emerson Deltav Unspecified Vulnerability

An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors. File data ot500393.nasl...

6.4CVSS5.3AI score0.01886EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Rockwellautomation Factorytalk Improper Input Validation

In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service RdcyHost.exe does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. File data ot500394.nasl...

5.8CVSS5.9AI score0.01099EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.26 views

Siemens Sicam Missing Authentication for Critical Function

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device. File data ot500482.nasl...

5CVSS4.2AI score0.00826EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.25 views

Rockwellautomation Micrologix Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...

7.5CVSS3.3AI score0.01719EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.22 views

Emerson Rx3i Improper Input Validation

GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versionsEnd of Life may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service...

7.8CVSS4.9AI score0.01549EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Emerson Deltav Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

SQL injection vulnerability in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to execute arbitrary SQL commands via unspecified vectors. File data ot500428.nasl...

7.5CVSS6.7AI score0.01511EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.22 views

Softwaretoolbox Top Out-of-bounds Write

KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, ar...

6.4CVSS4.3AI score0.04941EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.22 views

Emerson Deltav Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable due to improper path validation which may allow an attacker to replace executable files. File data ot500438.nasl...

6.5CVSS5.1AI score0.02185EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.14 views

Emerson Deltav Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Cross-site scripting XSS vulnerability in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. File data ot500413.nasl...

4.3CVSS4.2AI score0.01333EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Siemens Sicam Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network. File data...

7.5CVSS5.2AI score0.01889EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.26 views

Yokogawa Centum Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 includes CENTUM CS 3000 Small R3.08.10 to R3.09.50, CENTUM VP includes CENTUM VP Small, Basic R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to crea...

7.5CVSS4AI score0.02065EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.30 views

Rockwellautomation Factorytalk Improper Input Validation

A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device. File data ot500455.nasl...

7.8CVSS5.3AI score0.01598EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2020/08/10 12:00 a.m.28 views

Tridium Niagara Improper Authentication

A specific utility may allow an attacker to gain read access to privileged files in the Niagara AX 3.8u4 JACE 3e, JACE 6e, JACE 7, JACE-8000, Niagara 4.4u3 JACE 3e, JACE 6e, JACE 7, JACE-8000, and Niagara 4.7u1 JACE-8000, Edge 10. File data ot500383.nasl...

4.4CVSS4.3AI score0.00354EPSS
SaveExploits0References2
Rows per page