47 matches found
CVE-2020-7007
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the attacker may execute arbitrary codes or target the device, causing it to go out of service...
CVE-2020-7001
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed...
EUVD-2020-28137
Malware in sbrugna...
EUVD-2020-28119
Malware in sbrugna...
EUVD-2020-28139
Malware in sbrugna...
EUVD-2020-28141
Malware in sbrugna...
EUVD-2020-28121
Malware in sbrugna...
EUVD-2020-28131
Malware in sbrugna...
EUVD-2020-28147
Malware in sbrugna...
CVE-2020-6981
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication...
CVE-2020-6997
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext...
CVE-2020-6991
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force...
CVE-2020-6999
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer...
CVE-2020-6979
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered...
Moxa EDS-G516E and EDS-510E Series Ethernet Switches Weak Password Requirements (CVE-2020-6991)
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Moxa EDS-G516E and EDS-510E Series Ethernet Switches Cleartext Transmission of Sensitive Information (CVE-2020-6997)
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Buffer overflow
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer...
CVE-2020-6999
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer...