Lucene search
+L

386 matches found

ICS
ICS
•added 2020/01/23 12:00 a.m.•58 views

GE CARESCAPE, ApexPro, and Clinical Information Center systems

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station CSCS and Clinical Information Center CIC systems, CARESCAPE B450, B650, B850 Monitors Vulnerabilities:...

10CVSS10AI score0.04932EPSS
SaveExploits0References5
Penetration Testing Lab
Penetration Testing Lab
•added 2019/10/28 9:28 a.m.•92 views

Persistence – Port Monitors

The print spooler service is responsible for managing printing jobs in Windows operating systems. Interaction with the service is performed through the Print Spooler API which contains a function AddMonitor that can be used to install local port monitors and connects the configuration, data and...

3.1AI score
SaveExploits0
OSV
OSV
•added 2019/09/12 8:15 p.m.•17 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.2CVSS7.2AI score0.00687EPSS
SaveExploits0References1
NVD
NVD
•added 2019/09/12 8:15 p.m.•22 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.2CVSS7.1AI score0.00687EPSS
SaveExploits0References1
OSV
OSV
•added 2019/09/12 8:15 p.m.•8 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS5.8AI score0.01358EPSS
SaveExploits0References1
NVD
NVD
•added 2019/09/12 8:15 p.m.•22 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS7AI score0.01358EPSS
SaveExploits0References1
Prion
Prion
•added 2019/09/12 8:15 p.m.•24 views

Code injection

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

6.5CVSS7AI score0.00687EPSS
SaveExploits0References1Affected Software4
Prion
Prion
•added 2019/09/12 8:15 p.m.•26 views

Design/Logic Flaw

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

6.5CVSS6.9AI score0.01358EPSS
SaveExploits0References1Affected Software4
Cvelist
Cvelist
•added 2019/09/12 7:05 p.m.•38 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7AI score0.01358EPSS
SaveExploits0References1
CVE
CVE
•added 2019/09/12 7:05 p.m.•171 views

CVE-2019-13530

CVE-2019-13530 affects Philips IntelliVue WLAN portable patient monitors. Affected products include MP20‑MP90 (WLAN Version A, Firmware A.03.09), MP5/5SC (A.03.09), MP2/X2 and MX800/700/600 (WLAN Version B, Firmware A.01.09). The root cause is hard-coded credentials enabling FTP login to upload a...

7.2CVSS7AI score0.01358EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/09/12 7:02 p.m.•40 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.1AI score0.00687EPSS
SaveExploits0References1
CVE
CVE
•added 2019/09/12 7:02 p.m.•154 views

CVE-2019-13534

Philips IntelliVue WLAN portable patient monitors are affected by CVE-2019-13534. The vulnerability stems from the device downloading a file (code or firmware) from a remote location and executing it without sufficiently verifying the origin or integrity of the code. Affected products include Int...

7.2CVSS7.1AI score0.00687EPSS
SaveExploits0References1Affected Software1
Hacker One
Hacker One
•added 2019/08/23 9:47 p.m.•21 views

New Relic: User can run monitors at private locations, which he has no access to

@skavans discovered that insufficient validation was performed when configuring Synthetics monitors allowing deployment to arbitrary private locations with knowledge of the location ID: POST /accounts//validation.json HTTP/1.1 Host: synthetics.newrelic.com...

2AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2019/06/18 7:34 p.m.•184 views

Consumers Urged to Junk Insecure IoT Devices

More than 2 million connected security cameras, baby monitors and other IoT devices have serious vulnerabilities that have been publicly disclosed for more than two months – yet they are still without a patch or even any vendor response. Security researcher Paul Marrapese, who disclosed the flaws...

7.8AI score
SaveExploits0References10
Citrix
Citrix
•added 2019/03/23 12:00 a.m.•18 views

[Citrix Receiver 4.9.5000 for Windows] - Display Issues when user re-docks their Notebook on the docking station and reconnecting to Citrix Session with Multiple Monitors

This article is intended for Citrix administrators and technical teams only.Non-admin users must contact their company’s Help Desk/IT support team and can refer toCTX297149for more information Scenario : Users using notebooks and working with full screen sessions without desktop viewer to access...

6.7AI score
SaveExploits0
Fedora
Fedora
•added 2019/03/02 1:50 a.m.•44 views

[SECURITY] Fedora 29 Update: remmina-1.3.3-1.fc29

Remmina is a remote desktop client written in GTK+, aiming to be useful for system administrators and travelers, who need to work with lots of remote computers in front of either large monitors or tiny net-books. Remmina supports multiple network protocols in an integrated and consistent user...

9.8CVSS7AI score0.08156EPSS
SaveExploits2
RedHat Linux
RedHat Linux
•added 2018/11/07 11:04 p.m.•12 views

spice: Possible buffer overflow via invalid monitor configurations

A vulnerability was discovered in spice server's protocol handling. An authenticated attacker could send specially crafted messages to the spice server, causing out-of-bounds memory accesses, leading to parts of server memory being leaked or a crash...

8.8CVSS7.2AI score0.04204EPSS
SaveExploits0References4
IBM Security Bulletins
IBM Security Bulletins
•added 2018/11/01 3:30 p.m.•32 views

Security Bulletin: Multiple vulnerabilities in OpenSSL affect IBM Tivoli Netcool System Service Monitors/Application Service Monitors (CVE-2018-3737, CVE-2018-0732)

Summary The following security issues have been identified in OpenSSL 1.0.2, which is included as part of IBM Tivoli Netcool System Service Monitors/Application Service Monitors. Upgrading to OpenSSL 1.0.2p addresses these vulnerabilities. Vulnerability Details Relevant CVE Information: CVEID:...

7.5CVSS1AI score0.48831EPSS
SaveExploits1Affected Software1
IBM Security Bulletins
IBM Security Bulletins
•added 2018/10/30 6:30 p.m.•36 views

Security Bulletin: Multiple vulnerabilities in OpenSSL affect IBM Tivoli Netcool System Service Monitors/Application Service Monitors (CVE-2017-3735, CVE-2017-3736, CVE-2017-3737, CVE-2017-3738)

Summary The following security issues have been identified in OpenSSL 1.0.2, which is included as part of IBM Tivoli Netcool System Service Monitors/Application Service Monitors. Upgrading to OpenSSL 1.0.2o addresses these vulnerabilities. Vulnerability Details CVEID: CVE-2017-3735 DESCRIPTION:...

6.5CVSS6.7AI score0.83645EPSS
SaveExploits2Affected Software1
CNVD
CNVD
•added 2018/08/08 12:00 a.m.•13 views

Medtronic MyCareLink 24950 Patient Monitor and 24952 Patient Monitor Information Disclosure Vulnerability

The Medtronic MyCareLink 24950 Patient Monitor and 24952 Patient Monitor are both monitor devices from Medtronic, Inc. that are used to monitor a patient's vital signs. An information disclosure vulnerability exists in the Medtronic MyCareLink 24950 Patient Monitor and 24952 Patient Monitor all...

7.1CVSS6.5AI score0.00364EPSS
SaveExploits0References1
Rows per page
Query Builder