Lucene search
+L

1957 matches found

BDU FSTEC
BDU FSTEC
•added 2021/08/31 12:00 a.m.•15 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers Modicon M221, M100, and M200 lies in the small number of possible random values. This allows attackers to circumvent existing security restrictions by using brute-force attacks.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to the small number of possible random values. Exploiting this vulnerability can allow a malicious actor to bypass existing security restrictions by using brute-for...

8.3CVSS7.2AI score0.00296EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2021/08/31 12:00 a.m.•14 views

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, stems from insufficiently secure data encryption. This allows attackers to obtain the encryption key.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to insufficiently secure data encryption. Exploiting this vulnerability could allow a malicious actor to obtain the encryption key remotely...

7.8CVSS7.1AI score0.00296EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2021/08/30 12:00 a.m.•14 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in errors related to register data manipulation, allowing attackers to execute arbitrary commands.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium is related to errors in controlling registration data. Exploiting this vulnerability allows an attacker to execute arbitrary commands usi...

10CVSS8.1AI score0.02336EPSS
SaveExploits0References2Affected Software13
BDU FSTEC
BDU FSTEC
•added 2021/08/30 12:00 a.m.•19 views

The vulnerability of microprogrammed programmable logic controllers like Modicon and PacDrive lies in the lack of authentication for a critical function. This allows attackers to alter the device’s IP configuration.

The vulnerability of the microprogrammed logic controllers Modicon and PacDrive lies in the absence of authentication for the critical function. Exploiting this vulnerability allows an attacker to remotely alter the device’s IP configuration...

7.1CVSS7.5AI score0.0125EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2021/08/26 12:00 a.m.•15 views

The vulnerability of microprogrammed software for Modicon M218, M218, M241, M251, and M258 logic controllers lies in insufficient data authenticity checking, allowing attackers to execute arbitrary codes.

The vulnerability of microprogrammed software in Modicon M218, M218, M241, M251, and M258 logic controllers is related to insufficient verification of data authenticity. Exploiting this vulnerability can allow an attacker operating remotely to execute arbitrary codes...

5.4CVSS8.1AI score0.00692EPSS
SaveExploits0References2Affected Software4
BDU FSTEC
BDU FSTEC
•added 2021/08/25 12:00 a.m.•12 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium arises from incorrect restrictions on path names in the restricted access catalog. This allows unauthorized access by intruders to protected information.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium stems from incorrect restrictions on the path name in the restricted access catalog. Exploiting this vulnerability could allow an attacke...

7.8CVSS7.3AI score0.01494EPSS
SaveExploits0References3Affected Software4
BDU FSTEC
BDU FSTEC
•added 2021/08/18 12:00 a.m.•14 views

The vulnerability of microprogrammed software in Logic Controllers Modicon M218, Modicon M251, Modicon M241, and Modicon M258 lies in the lack of protection for transmitted data. This allows attackers to gain unauthorized access to the protected information.

The vulnerability of microprogrammed software in Logic Controllers Modicon M218, Modicon M251, Modicon M241, and Modicon M258 lies in the lack of protection for transmitted data. Exploiting this vulnerability can allow an intruder operating remotely to gain unauthorized access to protected...

5.4CVSS7.2AI score0.00876EPSS
SaveExploits0References3Affected Software4
NCSC
NCSC
•added 2021/08/12 12:00 a.m.•107 views

Vulnerabilities fixed in Schneider Electric EcoStruxure and Modicon products

Vulnerabilities have been fixed in Schneider Electric products. The vulnerabilities allow a malicious person to carry out attacks that lead to the following categories of damage: Denial-of-Service DoS Manipulation of data Remote code execution User rights Access to system data Schneider Electric...

10CVSS7.3AI score0.03493EPSS
SaveExploits12
Positive Technologies
Positive Technologies
•added 2021/08/10 12:00 a.m.•4 views

PT-2021-7778

Name of the Vulnerable Software and Affected Versions Modicon M580 CPU versions all Modicon M340 CPU versions all Modicon MC80 versions all Modicon Momentum Ethernet CPU versions all PLC Simulator for EcoStruxure Control Expert versions all PLC Simulator for EcoStruxure Process Expert versions al...

6.8CVSS5.9AI score0.00839EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•29 views

Schneider-electric Modicon Unspecified Vulnerability

A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 all references, all versions, that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictab...

5.5CVSS3.4AI score0.00734EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•25 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 all references, all versions that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221...

4.3CVSS3.3AI score0.00527EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•18 views

Schneider-electric Modicon Unspecified Vulnerability

A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. File data...

7.3CVSS4.6AI score0.00296EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•29 views

Schneider-electric Modicon Out-of-bounds Write

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause corruption of data, a crash, or code execution when uploading a specially crafted...

6.5CVSS4.1AI score0.01129EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•28 views

Schneider-electric Modicon Missing Encryption of Sensitive Data

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...

5.7CVSS3.7AI score0.00206EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•35 views

Schneider-electric Modicon Improper Input Validation

Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. File data ot500446.nasl...

7.8CVSS2.5AI score0.00978EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•36 views

Schneider-electric Modicon Out-of-bounds Write

Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller V5.0.0.7 and prior which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4...

7.5CVSS2.6AI score0.01387EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•17 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...

5.3CVSS1.3AI score0.00925EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•22 views

Schneider-electric Modicon Out-of-bounds Read

A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...

5.8CVSS4.6AI score0.00902EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•31 views

Schneider-electric Modicon Inadequate Encryption Strength

A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. File data...

7.3CVSS4.6AI score0.00296EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2021/08/10 12:00 a.m.•3 views

PT-2021-7828

Name of the Vulnerable Software and Affected Versions Modicon M580 CPU versions all Modicon M340 CPU versions all Modicon MC80 versions all Modicon Momentum Ethernet CPU versions all PLC Simulator for EcoStruxure Control Expert versions all PLC Simulator for EcoStruxure Process Expert versions al...

7.8CVSS5.5AI score0.00937EPSS
SaveExploits0References6