Lucene search
+L

1689 matches found

BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.10 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the insufficient checking of unusual or exceptional states. This allows a intruder to trigger a malfunction in maintenance by using a specially crafted HTTP packet.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the insufficient testing of unusual or exceptional states. Exploiting this vulnerability can allow an attacker operating remotely...

7.8CVSS7.2AI score0.01181EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.12 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the ability to disclose information, allowing unauthorized access to protected data.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium is related to the disclosure of information. Exploiting this vulnerability can allow unauthorized individuals to gain unauthorized access...

7.8CVSS7.2AI score0.01379EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2021/09/02 12:0 a.m.8 views

Schneider Electric Modicon M580 CPU 缓冲区错误漏洞

The Schneider Electric Modicon M580 CPU is a processor module for an M580 Ethernet programmable automation controller from Schneider Electric France. A buffer error vulnerability exists in the Schneider Electric Modicon M580 CPU that stems from the presence of an improperly restricted operation...

6.5CVSS7.3AI score0.00839EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/09/02 12:0 a.m.7 views

Schneider Electric Modicon M580 CPU 代码问题漏洞

The Schneider Electric Modicon M580 CPU is a processor module for the M580 Ethernet programmable automation controller from Schneider Electric, France. A code issue vulnerability exists in the Schneider Electric Modicon M580 CPU that stems from the presence of a null pointer dereference in the...

7.5CVSS7.6AI score0.00937EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.10 views

The vulnerability of the microprogrammed software of Schneider Electric’s Modicon M340 programmable logic controllers lies in the insufficient checking of unusual or exceptional states. This allows a intruder to trigger a malfunction during maintenance.

The vulnerability of the microprogrammed software of Schneider Electric’s Modicon M340 programmable logic controller is related to insufficient testing of unusual or exceptional states. Exploiting this vulnerability could allow a malicious actor to cause malfunctions during maintenance operations...

7.8CVSS7.2AI score0.01155EPSS
SaveExploits0References2Affected Software3
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.8 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for a critical function, allowing attackers to execute arbitrary commands.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for critical functions. Exploiting this vulnerability allows an attacker operating remotely to...

8.5CVSS8AI score0.0222EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.12 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium lies in insufficient testing for unusual or exceptional states. This allows a intruder to trigger malfunctions during maintenance.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium lies in insufficient testing for unusual or exceptional states. Exploiting this vulnerability can allow an attacker operati...

7.8CVSS7.2AI score0.01382EPSS
SaveExploits0References2Affected Software2
BDU FSTEC
BDU FSTEC
added 2021/08/31 12:0 a.m.8 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers Modicon M221, M100, and M200 stems from the lack of encryption measures for protected data. This allows attackers to obtain the encryption key.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to the lack of encryption measures for protected data. Exploiting this vulnerability can allow a remote attacker to obtain the encryption key...

7.8CVSS6.1AI score0.00203EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/31 12:0 a.m.9 views

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, stems from insufficiently secure data encryption. This allows attackers to obtain the encryption key.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to insufficiently secure data encryption. Exploiting this vulnerability could allow a malicious actor to obtain the encryption key remotely...

7.8CVSS7.1AI score0.00292EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/31 12:0 a.m.11 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers Modicon M221, M100, and M200 lies in the small number of possible random values. This allows attackers to circumvent existing security restrictions by using brute-force attacks.

The vulnerability of the microprogrammed logic controllers from Schneider Electric, such as Modicon M221, M100, and M200, is related to the small number of possible random values. Exploiting this vulnerability can allow a malicious actor to bypass existing security restrictions by using brute-for...

8.3CVSS7.2AI score0.00292EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/30 12:0 a.m.12 views

The vulnerability of microprogrammed programmable logic controllers like Modicon and PacDrive lies in the lack of authentication for a critical function. This allows attackers to alter the device’s IP configuration.

The vulnerability of the microprogrammed logic controllers Modicon and PacDrive lies in the absence of authentication for the critical function. Exploiting this vulnerability allows an attacker to remotely alter the device’s IP configuration...

7.1CVSS7.5AI score0.0125EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2021/08/30 12:0 a.m.8 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in errors related to register data manipulation, allowing attackers to execute arbitrary commands.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium is related to errors in controlling registration data. Exploiting this vulnerability allows an attacker to execute arbitrary commands usi...

10CVSS8.1AI score0.02239EPSS
SaveExploits0References2Affected Software13
BDU FSTEC
BDU FSTEC
added 2021/08/26 12:0 a.m.9 views

The vulnerability of microprogrammed software for Modicon M218, M218, M241, M251, and M258 logic controllers lies in insufficient data authenticity checking, allowing attackers to execute arbitrary codes.

The vulnerability of microprogrammed software in Modicon M218, M218, M241, M251, and M258 logic controllers is related to insufficient verification of data authenticity. Exploiting this vulnerability can allow an attacker operating remotely to execute arbitrary codes...

5.4CVSS8.1AI score0.00675EPSS
SaveExploits0References2Affected Software4
BDU FSTEC
BDU FSTEC
added 2021/08/25 12:0 a.m.6 views

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium arises from incorrect restrictions on path names in the restricted access catalog. This allows unauthorized access by intruders to protected information.

The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium stems from incorrect restrictions on the path name in the restricted access catalog. Exploiting this vulnerability could allow an attacke...

7.8CVSS7.3AI score0.01475EPSS
SaveExploits0References3Affected Software4
BDU FSTEC
BDU FSTEC
added 2021/08/18 12:0 a.m.8 views

The vulnerability of microprogrammed software in Logic Controllers Modicon M218, Modicon M251, Modicon M241, and Modicon M258 lies in the lack of protection for transmitted data. This allows attackers to gain unauthorized access to the protected information.

The vulnerability of microprogrammed software in Logic Controllers Modicon M218, Modicon M251, Modicon M241, and Modicon M258 lies in the lack of protection for transmitted data. Exploiting this vulnerability can allow an intruder operating remotely to gain unauthorized access to protected...

5.4CVSS7.2AI score0.00855EPSS
SaveExploits0References3Affected Software4
NCSC
NCSC
added 2021/08/12 12:0 a.m.92 views

Vulnerabilities fixed in Schneider Electric EcoStruxure and Modicon products

Vulnerabilities have been fixed in Schneider Electric products. The vulnerabilities allow a malicious person to carry out attacks that lead to the following categories of damage: Denial-of-Service DoS Manipulation of data Remote code execution User rights Access to system data Schneider Electric...

10CVSS7.3AI score0.03348EPSS
SaveExploits12
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.26 views

Schneider-electric Modicon Unspecified Vulnerability

A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 all references, all versions, that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictab...

5.5CVSS3.4AI score0.00725EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.13 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...

5.3CVSS1.3AI score0.00925EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.23 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 all references, all versions that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221...

4.3CVSS3.3AI score0.00521EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.27 views

Schneider-electric Modicon Out-of-bounds Write

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause corruption of data, a crash, or code execution when uploading a specially crafted...

6.5CVSS4.1AI score0.01082EPSS
SaveExploits0References2
Rows per page
Query Builder