CVE-2018-7857
CVE-2018-7857 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. It is described as CWE-248 Uncaught Exception: writing out-of-bounds variables to the controller over Modbus can cause a Denial of Service . The entry lists CVSSv3.1 base score 7.5 (HIGH) and CVSSv2 5.0 (MEDIU...
CVE-2018-7857
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus...
CVE-2018-7856
The CVE-2018-7856 entry concerns Schneider Electric Modicon PLCs (M580, M340, Quantum, Premium). The vulnerability is a CWE-248 Uncaught Exception leading to potential denial of service when writing invalid memory blocks to the controller over Modbus. Affected software/hardware is the Modicon fam...
CVE-2018-7856
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus...
CVE-2018-7855
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus...
CVE-2018-7855
CVE-2018-7855 affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. The root cause is an uncaught exception when handling invalid breakpoint parameters sent over Modbus, which can trigger a Denial of Service with partial availability impact. Connected documents confirm the affe...
CVE-2018-7854
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus...
CVE-2018-7854
CVE-2018-7854 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. The issue is a CWE-248 Uncaught Exception that can cause denial of service when invalid debug parameters are sent over Modbus. The provided documents confirm affected models and the root cause (uncaught except...
CVE-2018-7853
CVE-2018-7853 affects Schneider Electric Modicon PLCs (M580, M340, Quantum, Premium). The vulnerability is a CWE-248 Uncaught Exception that could cause a denial of service when the controller reads invalid physical memory blocks over Modbus. The NVD entry lists CVSS-3.1 base metrics: Network att...
CVE-2018-7852
CVE-2018-7852 affects Schneider Electric Modicon M580 family (M580, M340, Quantum, Premium). The issue is CWE-248 Uncaught Exception leading to denial of service when an invalid private command parameter is sent to the controller over Modbus/UMAS. Talos advisories describe multiple DoS scenarios ...
CVE-2018-7852
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus...
CVE-2018-7852
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus...
CVE-2018-7845
CVE-2018-7845 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. The vulnerability is CWE-125: Out-of-bounds Read, allowing disclosure of unexpected data when reading specific memory blocks over Modbus. Impact is data disclosure; no exploitation details are provided in the ...
CVE-2018-7845
A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus...
CVE-2018-7850
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software...
CVE-2018-7850
CVE-2018-7850 affects Schneider Electric Modicon controllers (M580, M340, Quantum, Premium) and relates to CWE-807 (Reliance on Untrusted Inputs in a Security Decision). The vulnerability could cause invalid information displayed in Unity Pro software due to a trust boundary issue in input handli...
CVE-2018-7847
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus...
CVE-2018-7847
CVE-2018-7847 affects Schneider Electric Modicon M580/M340/Quantum/Premium PLCs via Modbus; Talos confirms an unauthenticated UMAS file-write vulnerability in Modicon M580 firmware SV2.70 that can overwrite the device strategy/configuration, potentially enabling code execution and wide impact. Th...
CVE-2018-7842
The CVE-2018-7842 issue affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. Root cause: CWE-290 Authentication Bypass by Spoofing enabling brute-forcing of Modbus parameters to gain elevated privileges. Impact: elevation of privilege and potential unauthorized control of dev...
CVE-2018-7848
CVE-2018-7848 is an information-disclosure flaw in Schneider Electric Modicon controllers (M580, M340, Quantum, Premium) exploitable via the UMAS strategy read path. A specially crafted UMAS read of the programmed strategy (function code 0x34) can reveal plaintext SNMP community strings and other...