Lucene search
K

49 matches found

Positive Technologies
Positive Technologies
added 2025/02/25 12:0 a.m.3 views

PT-2025-7803 · Benner · Benner Modernanet

Name of the Vulnerable Software and Affected Versions: Benner ModernaNet versions up to 1.1.0 Description: A critical issue affects some unknown functionality of the file /Home/JS CarregaCombo?formName=DADOS PESSOAIS PLANO&additionalCondition=&insideParameters=&elementToReturn=DADOS PESSOAIS...

9.8CVSS7.7AI score0.0059EPSS
Exploits1References8
CNNVD
CNNVD
added 2025/02/25 12:0 a.m.3 views

Benner ModernaNet 注入漏洞

Benner ModernaNet is a diagnostic center application from Benner. An injection vulnerability exists in Benner ModernaNet version 1.1.0 and prior versions, which stems from the /AGE0000700/GetHorariosDoDia file containing a SQL injection issue...

9.8CVSS7.9AI score0.0059EPSS
Exploits1References5
CNNVD
CNNVD
added 2025/02/24 12:0 a.m.2 views

Benner ModernaNet 安全漏洞

Benner ModernaNet is a diagnostic center application from Benner. A security vulnerability exists in Benner ModernaNet version 1.2.0 and prior versions that stems from cross-site request forgery and could allow remote attacks...

6.5CVSS5AI score0.00324EPSS
Exploits1References1
CNNVD
CNNVD
added 2025/02/24 12:0 a.m.2 views

Benner ModernaNet 安全漏洞

Benner ModernaNet is a diagnostic center application from Benner. A security vulnerability exists in Benner ModernaNet version 1.1.0 and prior versions that stems from cross-site request forgery and could allow remote attacks...

8.8CVSS4.9AI score0.00342EPSS
Exploits1References1
CNNVD
CNNVD
added 2025/02/24 12:0 a.m.2 views

Benner ModernaNet 安全漏洞

Benner ModernaNet is a diagnostic center application from Benner. A security vulnerability exists in Benner ModernaNet version 1.1.0 and prior versions that stems from improper control of resource identifiers and could allow remote attacks...

7.5CVSS4.9AI score0.00616EPSS
Exploits1References1
NVD
NVD
added 2024/01/29 2:15 p.m.22 views

CVE-2024-23747

The Moderna Sistemas ModernaNet Hospital Management System 2024 is susceptible to an Insecure Direct Object Reference IDOR vulnerability. This vulnerability resides in the system's handling of user data access through a /Modernanet/LAUDO/LAU0000100/Laudo?id= URI. By manipulating this id parameter...

7.5CVSS7.5AI score0.00694EPSS
Exploits1References2
Prion
Prion
added 2024/01/29 2:15 p.m.15 views

Security feature bypass

The Moderna Sistemas ModernaNet Hospital Management System 2024 is susceptible to an Insecure Direct Object Reference IDOR vulnerability. This vulnerability resides in the system's handling of user data access through a /Modernanet/LAUDO/LAU0000100/Laudo?id= URI. By manipulating this id parameter...

5CVSS7.1AI score0.00694EPSS
Exploits1References2
CNNVD
CNNVD
added 2024/01/29 12:0 a.m.4 views

Moderna Sistemas ModernaNet Hospital Management System Security Vulnerability

Moderna Sistemas ModernaNet Hospital Management System is a hospital management system from Moderna Sistemas. A security vulnerability exists in Moderna Sistemas ModernaNet Hospital Management System version 2024, which arises from a security issue in the way the system handles access to user dat...

7.5CVSS6.6AI score0.00694EPSS
Exploits1References3
CVE
CVE
added 2024/01/29 12:0 a.m.56 views

CVE-2024-23747

CVE-2024-23747 concerns Moderna Sistemas ModernaNet Hospital Management System 2024. The vulnerability is an Insecure Direct Object Reference (IDOR) in the handling of user data via the API endpoint path “/Modernanet/LAUDO/LAU0000100/Laudo?id=”. By manipulating the numeric/opaque id parameter, an...

7.5CVSS7.4AI score0.00694EPSS
Exploits1References2Affected Software1
Rows per page
Query Builder