Lucene search
+L

22 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•24 views

EUVD-2021-24852

Malware in sbrugna...

6.9CVSS6.8AI score0.00149EPSS
SaveExploits0References2
CNVD
CNVD
•added 2021/11/05 12:00 a.m.•83 views

Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120 has an unspecified vulnerability

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 contains a security vulnerability that could be...

6.9CVSS1.7AI score0.00234EPSS
SaveExploits0References1
CNVD
CNVD
•added 2021/11/05 12:00 a.m.•93 views

Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120 Data Validation Error Vulnerability

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to a data validation error that...

6.8CVSS3.1AI score0.00173EPSS
SaveExploits0References1
CNVD
CNVD
•added 2021/11/05 12:00 a.m.•50 views

Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120 has an unspecified vulnerability (CNVD-2022-77534)

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable rhythm management Crm programming...

6.8CVSS2.1AI score0.00425EPSS
SaveExploits0References1
CNVD
CNVD
•added 2021/11/05 12:00 a.m.•68 views

Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120 Access Control Error Vulnerability

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to an access control error that...

7.6CVSS2.9AI score0.00259EPSS
SaveExploits0References1
CNVD
CNVD
•added 2021/11/05 12:00 a.m.•63 views

Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120 Encryption Error Vulnerability

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to an encryption error that could...

6.9CVSS2AI score0.00149EPSS
SaveExploits0References1
NVD
NVD
•added 2021/10/04 6:15 p.m.•27 views

CVE-2021-38400

An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...

6.9CVSS0.00149EPSS
SaveExploits0References1
CVE
CVE
•added 2021/10/04 5:35 p.m.•60 views

CVE-2021-38400

CVE-2021-38400 affects Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120. Vulnerability: password hash stored/used with insufficient computational effort, allowing a physically proximate attacker with access to remove the device’s hard drive or craft a USB to extract th...

6.9CVSS6.7AI score0.00149EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2021/10/04 12:00 a.m.•6 views

PT-2021-22112

Name of the Vulnerable Software and Affected Versions Boston Scientific Zoom Latitude Model 3120 Description An attacker with physical access to the device can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the syst...

6.9CVSS0.00149EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/10/04 12:00 a.m.•10 views

CVE-2021-38400: Use of Password Hash With Insufficient Computational Effort

An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...

6.9CVSS5.8AI score0.00149EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/09/30 12:00 a.m.•20 views

Boston Scientific Zoom Latitude Programmer/Recorder/Monitor Model 3120 数据伪造问题漏洞

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to a data validation error that...

6.8CVSS6.6AI score0.00173EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2021/09/30 12:00 a.m.•21 views

Boston Scientific Zoom Latitude Programmer/Recorder/Monitor Model 3120 安全漏洞

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to an encryption error that could...

6.9CVSS6.6AI score0.00149EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2021/09/30 12:00 a.m.•19 views

Boston Scientific Zoom Latitude Programmer/Recorder/Monitor Model 3120 安全漏洞

The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable rhythm management Crm programming...

6.8CVSS6.5AI score0.00425EPSS
SaveExploits0References5
Prion
Prion
•added 2018/05/01 6:29 p.m.•24 views

Hardcoded credentials

Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

2.1CVSS4.7AI score0.00385EPSS
SaveExploits0References2
NVD
NVD
•added 2018/05/01 6:29 p.m.•33 views

CVE-2017-14012

Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS4.8AI score0.00272EPSS
SaveExploits0References2
NVD
NVD
•added 2018/05/01 6:29 p.m.•34 views

CVE-2017-14014

Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS4.7AI score0.00385EPSS
SaveExploits0References2
CVE
CVE
•added 2018/05/01 6:00 p.m.•69 views

CVE-2017-14012

Mode C: The CVE-2017-14012 entry concerns Boston Scientific ZOOM LATITUDE PRM Model 3120. The vulnerability is due to a hard-coded cryptographic key used to encrypt PHI before transfer to removable media, resulting in PHI not being encrypted at rest. Affected product: ZOOM LATITUDE PRM – Model 31...

4.6CVSS4.8AI score0.00272EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2018/05/01 6:00 p.m.•62 views

CVE-2017-14014

Summary of CVE-2017-14014 : The Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI before it is transferred to removable media. This creates a vulnerability (CWE-321: Use of Hard-coded Cryptographic Key) with CVSS3 base score 4.6 (vector AV:P/AC:L/PR...

4.6CVSS4.7AI score0.00385EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2018/05/01 12:00 a.m.•7 views

PT-2018-5613

Name of the Vulnerable Software and Affected Versions: Boston Scientific ZOOM LATITUDE PRM Model 3120 Description: The issue concerns the use of a hard-coded cryptographic key for encrypting Protected Health Information PHI before it is transferred to removable media. This could potentially...

4.6CVSS5.9AI score0.00385EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/01 12:00 a.m.•10 views

CVE-2017-14012: Missing Encryption of Sensitive Data

Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS5.5AI score0.00272EPSS
SaveExploits0References3
Rows per page
Query Builder