2040 matches found
CVE-2020-7559: Buffer Copy without Checking Size of Input
A CWE-120: Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially...
CVE-2020-28213: Download of Code Without Integrity Check
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when sending specially crafted requests over Modbus...
CVE-2020-28212: Improper Restriction of Excessive Authentication Attempts
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when a brute force attack is done over Modbus...
PT-2020-6315
Name of the Vulnerable Software and Affected Versions EcoStruxure Control Expert all versions Description A vulnerability exists in the PLC Simulator of EcoStruxure Control Expert software, related to improper check for unusual or exceptional conditions. This issue could cause a crash of the PLC...
PT-2020-6378
Name of the Vulnerable Software and Affected Versions EcoStruxure Control Expert all versions Description A buffer copy without checking the size of input issue exists in the PLC Simulator of EcoStruxure Control Expert software. This could cause a crash of the PLC simulator when receiving a...
PT-2020-16947
Name of the Vulnerable Software and Affected Versions EcoStruxureª Control Expert now Unity Pro all versions Description A CWE-494: Download of Code Without Integrity Check issue exists in the PLC Simulator that could cause unauthorized command execution when sending specially crafted requests ov...
PT-2020-6317 · Schneider Electric · Ecostruxure Control Expert
Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert all versions Description: The issue is related to the lack of restrictions on authentication attempts, which could allow a remote attacker to bypass the authentication procedure. This vulnerability may lead to...
Schneider Electric EcoStruxure Control Expert authorization issue vulnerability
EcoStruxure Control Expert is the universal programming, debugging and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A security vulnerability exists in PLC Simulator in EcoStruxure Control Expert. The vulnerability can be exploited by an attacker to...
isf
This is a Python-based framework for Industrial Control System ICS exploitation, similar to Metasploit. It's called ICSSploit and is a fork of the routersploit project. The framework is designed to be used for penetration testing and vulnerability assessment of industrial control systems. The...
Schneider Electric EcoStruxure Control Expert PLC Denial of Service Vulnerability
Schneider Electric EcoStruxure Control Expert formerly Unity Pro is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A denial of service vulnerability exists in EcoStruxure Control Expert's PLC simulator, which originates when a...
isf1
This is an offensive tool for Industrial Control Systems ICS exploitation. It is a Python-based framework, similar to Metasploit, designed for ICS exploitation. The framework is called ICSSploit and is a fork of the routersploit project. The tool has various modules for different types of ICS...
isf
This is an offensive tool for ICS exploitation. It is a Python-based framework for ICS exploitation, similar to Metasploit. The framework is based on the open-source project "routersploit" and is designed for exploitation of industrial control systems ICS. The tool provides a range of features,...
isf
This is an offensive tool for ICS exploitation. It is a Python-based framework for exploiting Industrial Control Systems ICS, similar to Metasploit. The framework, known as ICSSploit, is a fork of the routersploit project and is designed for ICS exploitation. It includes various modules for...
Modbus Banner Grabbing
This module grabs the banner of any device running the Modbus protocol by sending a request with Modbus Function Code 43 Read Device Identification. Modbus is a data communications protocol originally published by Modicon now Schneider Electric in 1979 for use with its programmable logic...
CVE-2020-7523
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver see security notification for versions which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileg...
CVE-2020-7523
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver see security notification for versions which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileg...
Privilege escalation
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver see security notification for versions which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileg...
CVE-2020-7523
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver see security notification for versions which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileg...
CVE-2020-7523
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver see security notification for versions which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileg...
CVE-2020-7523
Schneider Electric Modbus Serial Driver contains an improper privilege management vulnerability that could enable local privilege escalation when the Modbus Serial Driver service is invoked. The driver reportedly does not properly assign, modify, track, or check privileges for an actor, creating ...