Lucene search
+L

26 matches found

ICS
ICS
•added 2014/12/28 7:00 a.m.•109 views

Schneider Electric Serial Modbus Driver Buffer Overflow (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-086-01A Schneider Electric Serial Modbus Driver Buffer Overflow that was published March 27, 2014, on the NCCIC/ICS-CERT web site. Carsten Eiram of Risk-Based Security has identified a stack-based buffer overflo...

9.3CVSS7.4AI score0.22217EPSS
SaveExploits10References10
NVD
NVD
•added 2014/04/01 6:17 a.m.•24 views

CVE-2013-0662

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

9.3CVSS7.5AI score0.22217EPSS
SaveExploits10References5
Prion
Prion
•added 2014/04/01 6:17 a.m.•18 views

Stack overflow

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

9.3CVSS8.2AI score0.22217EPSS
SaveExploits10References5Affected Software12
CVE
CVE
•added 2014/03/28 7:00 p.m.•148 views

CVE-2013-0662

The CVE-2013-0662 vulnerability affects Schneider Electric’s Modbus Serial Driver (ModbusDrv.exe) used by multiple Schneider Electric products. A stack-based buffer overflow is triggered when a large value is specified in the Modbus Application Header, enabling remote code execution with the user...

9.3CVSS7.6AI score0.22217EPSS
SaveExploits10References5Affected Software13
Positive Technologies
Positive Technologies
•added 2014/03/28 12:00 a.m.•3 views

PT-2014-1965

Name of the Vulnerable Software and Affected Versions Schneider Electric Modbus Serial Driver versions 1.10 through 3.2 Description The issue is caused by multiple stack-based buffer overflows in ModbusDrv.exe, allowing remote attackers to execute arbitrary code via a large buffer-size value in a...

9.3CVSS0.22217EPSS
SaveExploits10References8
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/28 12:00 a.m.•6 views

CVE-2013-0662: Out-of-bounds Write

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

9.3CVSS6.7AI score0.22217EPSS
SaveExploits10References2
Rows per page
Query Builder