30 matches found
PT-2023-3836 · Wago · Wago 750-3X/-8X
Name of the Vulnerable Software and Affected Versions: WAGO 750-3x/-8x products affected versions not specified Description: The issue is related to uncontrolled resource consumption in the mentioned products, which may allow an unauthenticated remote attacker to cause a denial of service DoS of...
wago 750-8xx 资源管理错误漏洞
WAGO wago 750-8xx is a series of programmable logic controllers from the German company WAGO WAGO. The devices are specifically designed for use in industrial environments where digital computing operates electronic systems. A resource management error vulnerability exists in the WAGO 750-3x/-8x...
CVE-2023-0027
Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected...
CVE-2022-2967
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
CVE-2022-2967
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
CVE-2022-2967
Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data...
PT-2023-12985 · Prosyst · Prosys Opc Ua Simulation Server
Name of the Vulnerable Software and Affected Versions: Prosys OPC UA Simulation Server versions prior to 5.3.0-64 UA Modbus Server versions 1.4.18-5 and prior Description: The issue concerns insufficient protection of credentials, potentially allowing an attacker to obtain user credentials and ga...
Prosys OPC UA Simulation Server (Update A)
1. EXECUTIVE SUMMARY CVSS v3 6.5 --------- Begin Update A part 1 of 3 --------- ATTENTION: Low attack complexity Vendor: Prosys OPC Equipment: UA Simulation Server, UA Modbus Server --------- End Update A part 1 of 3 --------- Vulnerability: Insufficiently Protected Credentials 2. UPDATE...
CVE-2021-22816
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...
CVE-2021-22816
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...