CVE-2020-16850

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.8CVSS7.3AI score0.02143EPSS
SaveExploits0References2
Prion
Prion
•added 2020/11/30 10:15 p.m.•25 views

Input validation

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.8CVSS7.3AI score0.02143EPSS
SaveExploits0References2Affected Software12
Cvelist
Cvelist
•added 2020/11/30 9:34 p.m.•41 views

CVE-2020-16850

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.3AI score0.02143EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/11/30 12:00 a.m.•2 views

PT-2020-5562

Name of the Vulnerable Software and Affected Versions Mitsubishi MELSEC iQ-R Series PLCs version 49 Description The issue allows an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network, exposing Improper Input Validation. This results in a denial of...

7.8CVSS0.02143EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/11/30 12:00 a.m.•6 views

CVE-2020-16850: Improper Input Validation

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.8CVSS5.9AI score0.02143EPSS
SaveExploits0References3
OSV
OSV
•added 2020/06/10 8:15 p.m.•21 views

CVE-2020-13238

Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to...

7.5CVSS5.8AI score0.03336EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2020/06/10 7:53 p.m.•54 views

CVE-2020-13238

Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to...

7.3AI score0.03336EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2020/06/10 12:00 a.m.•4 views

PT-2020-13388

Name of the Vulnerable Software and Affected Versions Mitsubishi MELSEC iQ-R Series PLCs version 33 Description The issue allows attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, consuming excessive CPU time and resulting in a denial of servic...

7.8CVSS0.03336EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/06/10 12:00 a.m.•5 views

CVE-2020-13238: Uncontrolled Resource Consumption

Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to...

7.8CVSS5.8AI score0.03336EPSS