Lucene search
+L

661 matches found

Positive Technologies
Positive Technologies
•added 2021/11/19 12:00 a.m.•6 views

PT-2021-8056

Name of the Vulnerable Software and Affected Versions MicroLogix 1400 affected versions not specified Description The issue is related to insufficient protection of service data in the MicroLogix 1400 programmable logic controller's firmware. It may allow a remote attacker to gain unauthorized...

7.8CVSS6AI score
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2021/11/19 12:00 a.m.•5 views

PT-2021-8066

Name of the Vulnerable Software and Affected Versions MicroLogix 1400 affected versions not specified Description The issue is related to insufficient protection of service data in the programmable logic controller's firmware, which could allow an attacker to install third-party software...

7.2CVSS5.8AI score
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2021/11/19 12:00 a.m.•3 views

PT-2021-8060

Name of the Vulnerable Software and Affected Versions MicroLogix 1400 affected versions not specified Description The issue is related to errors in resource management in the firmware of MicroLogix 1400 programmable logic controllers. Exploitation of this issue could allow a remote attacker to ga...

10CVSS6AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•24 views

Rockwellautomation Micrologix Channel Accessible by Non-Endpoint

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

5CVSS3AI score0.02982EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•30 views

Rockwellautomation Micrologix Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...

7.5CVSS3.3AI score0.01795EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2021/08/10 12:00 a.m.•28 views

Rockwellautomation Micrologix Unspecified Vulnerability

An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000...

5CVSS2.4AI score0.05555EPSS
SaveExploits0References3
NVD
NVD
•added 2021/07/09 3:15 p.m.•40 views

CVE-2021-33012

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.6CVSS0.02637EPSS
SaveExploits0References1
Prion
Prion
•added 2021/07/09 3:15 p.m.•24 views

Denial of service

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

5CVSS8.5AI score0.02637EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2021/07/09 3:15 p.m.•8 views

CVE-2021-33012

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.6CVSS7AI score0.02637EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/07/09 2:03 p.m.•53 views

CVE-2021-33012

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.8AI score0.02637EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2021/07/09 2:03 p.m.•13 views

CVE-2021-33012

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

7.3AI score0.02637EPSS
SaveExploits0References1
CVE
CVE
•added 2021/07/09 2:03 p.m.•91 views

CVE-2021-33012

CVE-2021-33012 affects Rockwell Automation MicroLogix 1100 (all versions). A remote, unauthenticated attacker can send specially crafted commands to cause the PLC to fault when switched to RUN mode, yielding a denial-of-service condition. Root cause: Improper Input Validation (CWE-20). As per CIS...

8.6CVSS8.5AI score0.02637EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
•added 2021/07/09 12:00 a.m.•60 views

Allen Bradley Micrologix 1100 Input Validation Error Vulnerability

The Allen Bradley Micrologix 1100 is a programmable controller for industrial environments from Allen Bradley of the Netherlands. The device supports Ethernet access, online editing for monitoring and programming, an embedded Web server for controlling the device via a Web page, and an embedded L...

8.6CVSS6.6AI score0.02637EPSS
SaveExploits0
Positive Technologies
Positive Technologies
•added 2021/07/09 12:00 a.m.•6 views

PT-2021-20019

Name of the Vulnerable Software and Affected Versions Rockwell Automation MicroLogix 1100, all versions Description The issue allows a remote, unauthenticated attacker to send specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, resulting in a...

8.6CVSS0.02637EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/09 12:00 a.m.•9 views

CVE-2021-33012: Improper Input Validation

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.6CVSS5.9AI score0.02637EPSS
SaveExploits0References4
ICS
ICS
•added 2021/07/08 12:00 a.m.•59 views

Rockwell Automation MicroLogix 1100

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: MicroLogix 1100 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to create a...

8.6CVSS8.9AI score0.02637EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2021/07/08 12:00 a.m.•22 views

Allen Bradley Micrologix 1100 输入验证错误漏洞

The Allen Bradley Micrologix 1100 is a programmable controller for industrial environments from Allen Bradley of the Netherlands. The device supports Ethernet access, online editing for monitoring and programming, an embedded Web server for controlling the device via a Web page, and an embedded L...

8.6CVSS5.6AI score0.02637EPSS
SaveExploits0References4
NVD
NVD
•added 2021/06/03 1:15 p.m.•50 views

CVE-2021-32926

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

7.5CVSS0.02982EPSS
SaveExploits0References1
OSV
OSV
•added 2021/06/03 1:15 p.m.•17 views

CVE-2021-32926

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

7.5CVSS5.8AI score0.02982EPSS
SaveExploits0References1
Prion
Prion
•added 2021/06/03 1:15 p.m.•28 views

Race condition

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

5CVSS7.4AI score0.02982EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder