Race condition
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...
CVE-2021-32926
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...
CVE-2021-32926
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...
PT-2021-19975 · Rockwell Automation · Micro800 +1
Name of the Vulnerable Software and Affected Versions: Micro800 versions All MicroLogix 1400 versions 21 and later Description: This issue allows an attacker to intercept and replace a legitimate new password hash with an illegitimate one during an authenticated password change request. This...
Rockwell Automation Micro800 and MicroLogix 1400
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: Micro800, MicroLogix 1400 Vulnerability: Channel Accessible by Non-endpoint 2. RISK EVALUATION Successful exploitation of this vulnerability may result in denial-of-service conditions, which...
Rockwell Automation Micro 1400 安全漏洞
The Rockwell Automation MicroLogix 1400 is a programmable logic controller from Rockwell Automation, USA. A security vulnerability exists in the Rockwell Automation Micro800 and MicroLogix 1400. An attacker could use this vulnerability to intercept a password change request message containing a...
CVE-2021-22659
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
CVE-2021-22659
The connected documents confirm CVE-2021-22659 affects Rockwell Automation MicroLogix 1400 controllers running version 21.6 and earlier. A remote, unauthenticated attacker can send specially crafted Modbus packets to retrieve or modify random register values, which may trigger a buffer overflow a...
CVE-2021-22659
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
CVE-2021-22659
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
Rockwell Automation MicroLogix 1400 Buffer Overflow Vulnerability
Micrologix 1400 is a programmable logic controller from Rockwell Automation. A buffer overflow vulnerability exists in Rockwell Automation MicroLogix 1400 version 21.6 and earlier. An attacker can exploit this vulnerability by sending specially crafted Modbus packets to retrieve or modify random...
Rockwell Automation MicroLogix 1400 安全漏洞
Micrologix 1400 is a programmable logic controller from Rockwell Automation. A buffer overflow vulnerability exists in Rockwell Automation MicroLogix 1400 version 21.6 and earlier. An attacker can exploit this vulnerability by sending specially crafted Modbus packets to retrieve or modify random...
CVE-2020-6980
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol SMTP account data is saved in RSLogix 500, a local attacker with access to a...
CVE-2020-6990
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file...
CVE-2020-6988
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix...
CVE-2020-6984
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable...
CVE-2020-6984
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable...
Authentication flaw
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix...
Authentication flaw
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol SMTP account data is saved in RSLogix 500, a local attacker with access to a...
Hardcoded credentials