CVE-2022-32537 Medtronic MiniMed 600 Series Pump System Communication Issue

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced...

4.8CVSS5.8AI score0.00328EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/06/28 12:00 a.m.•1 views

CVE-2019-10964: Improper Access Control

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker...

8.8CVSS5.9AI score0.01234EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2018/08/14 12:00 a.m.•27 views

The vulnerability of Medtronic MiniMed medical equipment, related to insufficient protection of transmitted information, allows a perpetrator to disclose protected information.

The vulnerability of Medtronic MiniMed 508, 522, 523, 523K, 551, 722, 723, 723K, and 751 medical devices lies in the transmission of protected information in an unencrypted form. Exploiting this vulnerability could allow an intruder to disclose protected information...

6.5CVSS5.5AI score0.00474EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2018/08/14 12:00 a.m.•74 views

The vulnerability of Medtronic MiniMed medical equipment is caused by deficiencies in the authentication mechanism, allowing unauthorized users to replicate intercepted requests.

The vulnerability of Medtronic MiniMed 508, 522, 523, 523K, 551, 722, 723, 723K, and 751 insulin pumps is related to deficiencies in the authentication mechanism. Exploiting this vulnerability allows attackers to bypass the authentication process by executing a hijacked request...

6.5CVSS5.5AI score0.00712EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/13 12:00 a.m.•3 views

CVE-2018-10634: Cleartext Transmission of Sensitive Information

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers...

5.3CVSS6.2AI score0.00474EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/13 12:00 a.m.•4 views

CVE-2018-14781: Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS6.3AI score0.00712EPSS