Lucene search
+L

14 matches found

RedhatCVE
RedhatCVE
added 2026/06/05 7:40 p.m.17 views

CVE-2025-4386

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​...

6.8CVSS5.4AI score0.00157EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2026/05/07 12:00 a.m.21 views

Medtronic MyCareLink Patient Monitor 安全漏洞

Medtronic MyCareLink Patient Monitor is an open-source monitoring system developed by Medtronic in the United States. The Medtronic MyCareLink Patient Monitor has a security vulnerability, which stems from its internal serial interface. This vulnerability could allow attackers with physical acces...

6.8CVSS5.8AI score0.00157EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/12/05 8:32 p.m.12 views

CVE-2025-12994

Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025...

5.3CVSS7AI score0.00292EPSS
SaveExploits0References1
OSV
OSV
added 2025/12/04 8:16 p.m.10 views

CVE-2025-12997

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: befo...

3.1CVSS5.8AI score0.00181EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/12/04 8:04 p.m.7 views

CVE-2025-12997

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: befo...

2.2CVSS6.1AI score0.00181EPSS
SaveExploits0References1
EUVD
EUVD
added 2025/12/04 8:03 p.m.9 views

EUVD-2025-201285

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025...

8.1CVSS6.6AI score0.00326EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2025/12/04 12:00 a.m.10 views

Medtronic CareLink Network 安全漏洞

Medtronic CareLink Network is an open source platform for remote monitoring of cardiac patients by Medtronic in the United States. A security vulnerability exists in versions of Medtronic CareLink Network prior to December 4, 2025, which stems from a local attacker being able to view plaintext...

4.1CVSS6.3AI score0.00106EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2025/12/04 12:00 a.m.16 views

PT-2025-49127

Name of the Vulnerable Software and Affected Versions Medtronic CareLink Network versions prior to December 4, 2025 Description An Insecure Direct Object Reference issue exists in Medtronic CareLink Network. An authenticated attacker, possessing access to specific device and user information, can...

3.1CVSS6.4AI score0.00181EPSS
SaveExploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.9 views

EUVD-2018-17216

Malware in sbrugna...

5.3CVSS5.8AI score0.0039EPSS
SaveExploits0References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.10 views

EUVD-2018-17218

Malware in sbrugna...

5.7CVSS6.1AI score0.00739EPSS
SaveExploits0References5
ATTACKERKB
ATTACKERKB
added 2025/07/24 3:30 a.m.6 views

CVE-2025-4395

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS5.9AI score0.0027EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2018/12/14 3:00 p.m.31 views

CVE-2018-18984 Medtronic 9790, 2090 CareLink, and 29901 Encore Programmers Missing Encryption of Sensitive Data

Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest...

4.6CVSS4.7AI score0.00315EPSS
SaveExploits0References3
Prion
Prion
added 2018/08/10 6:29 p.m.20 views

Design/Logic Flaw

A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable...

3.8CVSS5.2AI score0.00364EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2018/07/03 1:29 a.m.4 views

CVE-2018-8868

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...

6.9CVSS5.7AI score0.00333EPSS
SaveExploits0References3
Rows per page
Query Builder