1859 matches found
EUVD-2025-203848
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function nullconvert is called based of...
Radiometer Products 安全漏洞
Radiometer Products is a line of medical diagnostic instruments from the Danish company Radiometer. A security vulnerability exists in Radiometer Products that stems from a weakness in the analyzer application software that could lead to remote code execution and unauthorized device management wh...
Radiometer Products 安全漏洞
Radiometer Products is a line of medical diagnostic instruments from the Danish company Radiometer. A security vulnerability exists in Radiometer Products that stems from a weakness in the design of the application software access control implementation that could result in a physical accessor...
CVE-2025-53619
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function nullconvert is called based of...
DEBIAN-CVE-2025-48429
An out-of-bounds read vulnerability exists in the RLECodec::DecodeByStreams functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to leaking heap data. An attacker can provide a malicious file to trigger this vulnerability...
DEBIAN-CVE-2025-53619
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function nullconvert is called based of...
DEBIAN-CVE-2025-53618
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function grayscaleconvert is called base...
CVE-2025-53619
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function nullconvert is called based of...
CVE-2025-53618
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function grayscaleconvert is called base...
SQL Injection Vulnerability in Remote Medical Comprehensive Service Platform of Beijing Divine Vision Han Technology Co. Ltd (CNVD-C-2025-987341)
Ltd. is a deep-rooted enterprise in the field of visualization. A SQL injection vulnerability exists in the remote medical integrated service platform of Beijing Shenzhou Vision Han Technology Co. Ltd, which can be exploited by attackers to obtain sensitive information from the database...
A Practical Framework for Evaluating Medical AI Security: Reproducible Assessment of Jailbreaking and Privacy Vulnerabilities across Clinical Specialties
Medical Large Language Models LLMs are increasingly deployed for clinical decision support across diverse specialties, yet systematic evaluation of their robustness to adversarial misuse and privacy leakage remains inaccessible to most researchers. Existing security benchmarks require GPU cluster...
SQL Injection Vulnerability in Remote Medical Comprehensive Service Platform of Beijing Divine Vision Han Technology Co. Ltd (CNVD-C-2025-980402)
Ltd. is a deep-rooted enterprise in the field of visualization. A SQL injection vulnerability exists in the remote medical integrated service platform of Beijing Shenzhou Vision Han Technology Co. Ltd, which can be exploited by attackers to obtain sensitive information from the database...
CVE-2025-62575 Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account 'nmdbuser' and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures...
CVE-2025-62575 Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account 'nmdbuser' and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures...
CVE-2025-62575
CVE-2025-62575 concerns NMIS/BioDose software (V22.02 and earlier) that relies on a Microsoft SQL Server database. The root cause is that the default SQL account nmdbuser (and other created accounts) has the sysadmin role, enabling potential remote code execution through certain built‑in stored p...
CVE-2025-64778 Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials
NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database...
CVE-2025-64778
CVE-2025-64778 concerns NMIS/BioDose software V22.02 and earlier, where executables ship with hard-coded plaintext passwords. The root cause is embedded credentials in binary files, enabling unauthorized access to both the application and the SQL Server database under affected deployments. Public...
CVE-2025-61940 Mirion Medical EC2 Software NMIS BioDose Use of Client-Side Authentication
NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest...
CVE-2025-64298 Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and...
CVE-2025-64642 Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries...