CVE-2020-27278
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface...
Hardcoded credentials
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface...
Input validation
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files...
Information disclosure
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files...
CVE-2020-27290
The CVE-2020-27290 case concerns Hamilton Medical AG T1-Ventilator, affected in versions 2.2.3 and prior. The vulnerability is an information disclosure flaw enabling attackers with physical access to the device’s configuration interface logs to obtain valid checksums for tampered configuration f...
CVE-2020-27290
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files...
CVE-2020-27282
The connected documents provide concrete details for CVE-2020-27282 affecting Hamilton Medical AG T1-Ventilator (Versions 2.2.3 and earlier). The vulnerability is an XML validation weakness in the ventilator’s configuration interface that, if exploited by a user with physical access, can render t...
CVE-2020-27278
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface...
CVE-2020-27278
The CVE-2020-27278 issue affects Hamilton Medical AG’s T1-Ventilator (versions 2.2.3 and earlier). The vulnerability arises from hard-coded credentials in the device’s configuration interface, enabling attackers with physical access to obtain admin privileges. Public sources also document related...
Researchers Unearth Links Between SunCrypt and QNAPCrypt Ransomware
SunCrypt, a ransomware strain that went on to infect several targets last year, may be an updated version of the QNAPCrypt ransomware, which targeted Linux-based file storage systems, according to new research. "While the two ransomware families are operated by distinct different threat actors on...
SQL Injection Vulnerability in the Anti-Desertion Platform of Zhejiang Dahua Technology Co. Ltd. for Medical Treatment Outside the Company (CNVD-2021-21757)
Zhejiang Dahua Technology Co., Ltd. is a video-centered intelligent IOT solution provider and operation service provider. A SQL injection vulnerability exists in the anti-evasion platform of Zhejiang Dahua Technology Co. An attacker can exploit the vulnerability to obtain sensitive information in...
OpenEMR SQL Injection Vulnerability (CNVD-2021-13205)
OpenEMR is an open source medical management system from the OpenEMR Openemr community. The system can be used for medical practice management, electronic medical records, prescription writing and medical billing requests. A SQL injection vulnerability exists in OpenEMR that stems from a lack of...
Unauthorized Access Vulnerability in Electronic Medical Record Query System of Nanjing Nalong Technology Co.
Nanjing Nalon Technology Co., Ltd. is a company dedicated to cardiac electrophysiology solutions. An unauthorized access vulnerability exists in the electronic medical record query system of Nanjing Nalong Technology Co. Ltd, which can be exploited by attackers to obtain sensitive information...
CISA Releases Joint Cybersecurity Advisory on Exploitation of Accellion File Transfer Appliance
The cybersecurity authorities of Australia, New Zealand, Singapore, the United Kingdom, and the United States have released Joint Cybersecurity Advisory AA21-055A: Exploitation of Accellion File Transfer Appliance. Cyber actors worldwide have exploited vulnerabilities in Accellion File Transfer...
OpenEMR Operating System Command Injection Vulnerability
OpenEMR is an open source medical management system from the OpenEMR Openemr community. The system can be used for medical practice management, electronic medical records, prescription writing and medical billing requests. An operating system command injection vulnerability exists in the OpenEMR...
OpenEMR SQL Injection Vulnerability (CNVD-2021-12109)
OpenEMR is a medical practice management software that also supports electronic medical records EMR. A SQL injection vulnerability exists in interface/reports/immunizationreport.php in OpenEMR versions prior to 5.0.2.5. A remote authenticated attacker can exploit this vulnerability to execute...
OpenEMR SQL Injection Vulnerability (CNVD-2021-12108)
OpenEMR is a medical practice management software that also supports electronic medical records EMR. A SQL injection vulnerability exists in interface/main/finder/patientselect.php in OpenEMR versions prior to 5.0.2.5. A remote authenticated attacker can exploit this vulnerability to execute...
OpenEMR SQL Injection Vulnerability (CNVD-2021-11076)
OpenEMR is a medical practice management software that also supports electronic medical records EMR. A SQL injection vulnerability exists in interface/usergroup/usergroupadmin.php in OpenEMR versions prior to 5.0.2.5. A remote authenticated attacker can exploit this vulnerability to execute...
Extortion, precision malware, and ruthless scams. Read the State of Malware 2021 report
Last year, threat actors took advantage of the COVID-19 public health crisis in a way previously considered unimaginable, not only preying on uncertainty and fear during the initial months of the global pandemic, but retooling attack methods, reneging on promises, strengthening malware, and...
Hamilton-T1