Lucene search
+L

117 matches found

Talos
Talos
added 2019/04/08 12:00 a.m.77 views

Capsule Technologies SmartLinx Neuron 2 restricted environment protection mechanism failure vulnerability

Summary A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in ful...

7.6CVSS7.3AI score0.00472EPSS
SaveExploits0
CNVD
CNVD
added 2018/11/08 12:00 a.m.13 views

Multiple Roche Device Permission License and Access Control Vulnerabilities (CNVD-2018-25430)

The Roche Accu-Chek Inform II Instrument, among others, is a handheld blood testing medical device from Roche, Switzerland. A privilege-permission and access-control vulnerability exists in a number of Roche devices, which could be exploited by an attacker to change the configuration...

6.8CVSS6.9AI score0.00467EPSS
SaveExploits0References1
OSV
OSV
added 2018/09/26 7:29 p.m.14 views

CVE-2018-8856

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS5.8AI score0.01103EPSS
SaveExploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.11 views

CVE-2018-8854

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...

7.5CVSS5.8AI score0.02226EPSS
SaveExploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.24 views

CVE-2018-8852

Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...

8.8CVSS7.7AI score0.01588EPSS
SaveExploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.11 views

CVE-2018-8848

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5CVSS5.8AI score0.02026EPSS
SaveExploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.10 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.8CVSS5.8AI score0.00801EPSS
SaveExploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.9 views

CVE-2018-8846

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...

6.1CVSS5.8AI score0.0146EPSS
SaveExploits0References3
Prion
Prion
added 2018/09/26 7:29 p.m.20 views

Code injection

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

5CVSS7.9AI score0.02026EPSS
SaveExploits0References3Affected Software1
attackerkb
attackerkb
added 2018/09/26 7:29 p.m.5 views

CVE-2018-8842

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to...

8.8CVSS5.5AI score0.00391EPSS
SaveExploits0References4
Prion
Prion
added 2018/09/26 7:29 p.m.23 views

Information disclosure

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to t...

5CVSS5.8AI score0.01876EPSS
SaveExploits0References3Affected Software1
attackerkb
attackerkb
added 2018/09/26 7:29 p.m.6 views

CVE-2018-8848

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5CVSS5.5AI score0.02026EPSS
SaveExploits0References4
attackerkb
attackerkb
added 2018/09/26 7:29 p.m.6 views

CVE-2018-8856

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS5.4AI score0.01103EPSS
SaveExploits0References4
Prion
Prion
added 2018/09/26 7:29 p.m.22 views

Cross site request forgery (csrf)

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

6.8CVSS8.9AI score0.00801EPSS
SaveExploits0References3Affected Software1
Prion
Prion
added 2018/09/26 7:29 p.m.19 views

Session fixation

Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...

6.8CVSS8.7AI score0.01588EPSS
SaveExploits0References3Affected Software1
attackerkb
attackerkb
added 2018/09/26 7:29 p.m.6 views

CVE-2018-8852

Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...

8.8CVSS5.5AI score0.01588EPSS
SaveExploits0References4
Prion
Prion
added 2018/09/26 7:29 p.m.19 views

Code injection

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...

5CVSS7.8AI score0.02226EPSS
SaveExploits0References3Affected Software1
Prion
Prion
added 2018/09/26 7:29 p.m.17 views

Design/Logic Flaw

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...

7.5CVSS9.4AI score0.03241EPSS
SaveExploits0References3Affected Software1
OSV
OSV
added 2018/09/26 7:29 p.m.9 views

CVE-2018-8842

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to...

8.8CVSS5.8AI score0.00391EPSS
SaveExploits0References3
attackerkb
attackerkb
added 2018/09/26 7:29 p.m.5 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.8CVSS5.5AI score0.00801EPSS
SaveExploits0References4
Rows per page