13 matches found
CVE-2019-25724
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
PT-2026-45813
Name of the Vulnerable Software and Affected Versions Dräger Infinity M300 versions VG2.x and earlier Description A network-based denial of service issue exists that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots. This can lead to the device...
EUVD-2019-6268
Malware in sbrugna...
EUVD-2024-47662
Malicious code in bioql PyPI...
Security Bulletin: IBM Common Cryptographic Architecture (CCA) is vulnerable to denial of service (CVE-2022-22423)
Summary Insufficient input validation in IBM Common Cryptographic Architecture CCA may affect Hardware Security Module HSM availability. An affected IBM 4767 or IBM 4769 HSM may be forced into a check-stop condition by specially-crafted requests from HSM users. Recovery from a check-stop conditio...
CVE-2024-6598
A denial-of-service attack is possible through the execution functionality of KNIME Business Hub 1.10.0 and 1.10.1. It allows an authenticated attacker with job execution privileges to execute a job that causes internal messages to pile up until there are no more resources available for processin...
Security Bulletin: Configuring Volume Throttling on Storwize V3500, V3700, V5000 and V7000 (Gen 2) with V7.5.0.0-V7.5.0.2 may cause a loss of access to data
Summary Abstract Changing the volume throttling attribute on a Storwize V3500, V3700, V5000 or V7000 Gen 2 system with V7.5.0.0-V7.5.0.2 may cause node canisters in the system to go offline with a node error 564, requiring manual recovery. Content Vulnerability Details Abstract Changing the volum...
PT-2021-2259 · Cisco · Snort
Name of the Vulnerable Software and Affected Versions: Cisco products affected versions not specified Description: The issue is related to improper handling of error conditions when processing Ethernet frames in the Snort detection engine, which could allow an unauthenticated, adjacent attacker t...
PT-2020-4458 · Cisco · Cisco Ftd +1
Name of the Vulnerable Software and Affected Versions: Cisco Adaptive Security Appliance ASA Software affected versions not specified Cisco Firepower Threat Defense FTD Software affected versions not specified Description: A vulnerability in the SSL/TLS session handler could allow an...
CVE-2020-3567
A vulnerability in the management REST API of Cisco Industrial Network Director IND could allow an authenticated, remote attacker to cause the CPU utilization to increase to 100 percent, resulting in a denial of service DoS condition on an affected device. The vulnerability is due to insufficient...
CVE-2020-3516 Cisco IOS XE Software Web UI Improper Input Validation Vulnerability
A vulnerability in the web server authentication of Cisco IOS XE Software could allow an authenticated, remote attacker to crash the web server on the device. The vulnerability is due to insufficient input validation during authentication. An attacker could exploit this vulnerability by entering...
The vulnerability of Cisco IOS XR routers, which allows a hacker to trigger a maintenance failure
The vulnerability of the Event Management Service router in Cisco IOS XR is related to resource management errors. Exploiting this vulnerability allows a malicious actor, operating remotely and without authentication, to cause service failures on the targeted device. The vulnerability stems from...