Lucene search
+L

951 matches found

Prion
Prion
added 2024/02/14 11:15 a.m.17 views

Command injection

Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command on the affected product...

7.8AI score0.01176EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2024/02/14 10:35 a.m.24 views

CVE-2024-23789

Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command on the affected product...

7.4AI score0.01176EPSS
SaveExploits0References3
CVE
CVE
added 2024/02/14 10:35 a.m.78 views

CVE-2024-23789

The CVE-2024-23789 issue affects SHARP Energy Management Controller with Cloud Services (JH-RVB1 / JH-RV11) versions B0.1.9.1 and earlier. Affected component is the OS command execution via a network-adjacent, unauthenticated attacker. The Red Hat/Red team documents corroborate “OS command inject...

9.8CVSS7.4AI score0.01176EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2024/02/14 10:15 a.m.18 views

CVE-2024-23783

Improper authentication vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to access the affected product without authentication...

8.8CVSS6.8AI score0.00519EPSS
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.8 views

CVE-2024-23787

Path traversal vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to obtain an arbitrary file in the affected product...

6.5CVSS5.9AI score0.00892EPSS
SaveExploits0References3
NVD
NVD
added 2024/02/14 10:15 a.m.20 views

CVE-2024-23788

Server-side request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to send an arbitrary HTTP request GET from the affected product...

9.1CVSS6.8AI score0.0081EPSS
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.3 views

CVE-2024-23784

Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected...

6.5CVSS5.8AI score0.00393EPSS
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.6 views

CVE-2024-23785

Cross-site request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a remote unauthenticated attacker to change the product settings...

6.5CVSS5.9AI score
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.7 views

CVE-2024-23788

Server-side request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to send an arbitrary HTTP request GET from the affected product...

8.1CVSS5.9AI score0.0081EPSS
SaveExploits0References3
NVD
NVD
added 2024/02/14 10:15 a.m.18 views

CVE-2024-23784

Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected...

6.5CVSS6.7AI score0.00393EPSS
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.5 views

CVE-2024-23783

Improper authentication vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to access the affected product without authentication...

8.8CVSS5.8AI score0.00519EPSS
SaveExploits0References3
NVD
NVD
added 2024/02/14 10:15 a.m.21 views

CVE-2024-23786

Cross-site scripting vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary script on the web browser of the user who is accessing the management page of the affected...

9.3CVSS6.6AI score0.00786EPSS
SaveExploits0References3
OSV
OSV
added 2024/02/14 10:15 a.m.5 views

CVE-2024-23786

Cross-site scripting vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary script on the web browser of the user who is accessing the management page of the affected...

9.3CVSS6AI score0.00786EPSS
SaveExploits0References3
NVD
NVD
added 2024/02/14 10:15 a.m.23 views

CVE-2024-23787

Path traversal vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to obtain an arbitrary file in the affected product...

7.5CVSS6.7AI score0.00892EPSS
SaveExploits0References3
Prion
Prion
added 2024/02/14 10:15 a.m.19 views

Improper access control

Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected...

7.3AI score0.00393EPSS
SaveExploits0References3
Prion
Prion
added 2024/02/14 10:15 a.m.21 views

Cross site request forgery (csrf)

Cross-site request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a remote unauthenticated attacker to change the product settings...

7.4AI score0.00357EPSS
SaveExploits0References3
Prion
Prion
added 2024/02/14 10:15 a.m.20 views

Authentication flaw

Improper authentication vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to access the affected product without authentication...

7.4AI score0.00519EPSS
SaveExploits0References3
Prion
Prion
added 2024/02/14 10:15 a.m.20 views

Server side request forgery (ssrf)

Server-side request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to send an arbitrary HTTP request GET from the affected product...

7.4AI score0.0081EPSS
SaveExploits0References3
Prion
Prion
added 2024/02/14 10:15 a.m.17 views

Path traversal

Path traversal vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to obtain an arbitrary file in the affected product...

7.3AI score0.00892EPSS
SaveExploits0References3
CVE
CVE
added 2024/02/14 10:10 a.m.77 views

CVE-2024-23788

CVE-2024-23788 affects Sharp Energy Management Controller with Cloud Services (JH-RV11/B0.1.9.1 and earlier). The issue is a server-side request forgery (SSRF) allowing a network-adjacent, unauthenticated attacker to send arbitrary HTTP GET requests from the affected device. Impact is high for co...

9.1CVSS7AI score0.0081EPSS
SaveExploits0References3Affected Software1
Rows per page
Query Builder