50 matches found
CVE-2021-22709
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF Configuration Group File fil...
CVE-2021-22710
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF Configuration Group File file is imported to IGS...
Prototype Pollution
Overview Affected versions of this package are vulnerable to Prototype Pollution. If an attacker submits a malicious INI file to an application that parses it with loadSharedConfigFiles , they will pollute the prototype on the application. This can be exploited further depending on the context. P...
CVE-2020-36167
An issue was discovered in the server in Veritas Backup Exec through 16.2, 20.6 before hotfix 298543, and 21.1 before hotfix 657517. On start-up, it loads the OpenSSL library from the Installation folder. This library in turn attempts to load the /usr/local/ssl/openssl.cnf configuration file, whi...
Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability
The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...
Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability
The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer error vulnerability exists in IGSS version 14.0.0.20247 and earlier, which stems...
Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability
The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...
Schneider Electric Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability
The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...
Cross site request forgery (csrf)
The Voo branded NETGEAR CG3700b custom firmware V2.02.03 allows CSRF against all /goform/ URIs. An attacker can modify all settings including WEP/WPA/WPA2 keys, restore the router to factory settings, or even upload an entire malicious configuration file...
CVE-2010-4170
The staprun runtime tool in SystemTap 1.3 does not properly clear the environment before executing modprobe, which allows local users to gain privileges by setting the MODPROBEOPTIONS environment variable to specify a malicious configuration file...