Lucene search
+L

53 matches found

attackerkb
attackerkb
•added 2021/05/26 8:15 p.m.•10 views

CVE-2021-22705

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert...

7.8CVSS7.1AI score0.00246EPSS
SaveExploits0References2
Prion
Prion
•added 2021/05/26 8:15 p.m.•25 views

Design/Logic Flaw

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert...

4.6CVSS7.4AI score0.00246EPSS
SaveExploits0References1Affected Software2
CVE
CVE
•added 2021/05/26 7:19 p.m.•87 views

CVE-2021-22705

CVE-2021-22705 describes an Improper Restriction of Operations within the Bounds of a Memory Buffer that could allow denial of service or unauthorized access to system information when interacting with a driver installed by Schneider Electric’s Vijeo Designer or EcoStruxure Machine Expert. The co...

7.8CVSS7.3AI score0.00246EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/05/26 7:19 p.m.•45 views

CVE-2021-22705

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert...

7.6AI score0.00246EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/26 12:00 a.m.•5 views

CVE-2021-22705: Improper Restriction of Operations within the Bounds of a Memory Buffer

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert...

7.8CVSS5.8AI score0.00246EPSS
SaveExploits0References2
ThreatPost
ThreatPost
•added 2020/11/12 4:52 p.m.•23 views

Bugs in Critical Infrastructure Gear Allow Sophisticated Cyberattacks

Two security vulnerabilities in Schneider Electric’s programmable logic controllers PLCs could allow attackers to compromise a PLC and move on to more sophisticated critical infrastructure attacks. PLCs are key pieces of equipment in environments such as electric utilities and factories. They...

0.4AI score
SaveExploits0References11
CNVD
CNVD
•added 2020/04/23 12:00 a.m.•17 views

Schneider Electric EcoStruxure Machine Expert-Basic or SoMachine Basic Injection Vulnerability

Schneider Electric EcoStruxure Machine Expert-Basic and SoMachine Basic are both products of Schneider Electric, France.Schneider Electric EcoStruxure Machine Expert-Basic is a PLC configuration application. The program is mainly used for programmable logic controller configuration, programming a...

9.8CVSS7.5AI score0.01596EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2020/04/22 7:15 p.m.•8 views

CVE-2020-7489

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

9.8CVSS8.5AI score0.01596EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2020/04/22 6:15 p.m.•10 views

CVE-2020-7489

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

7.4AI score0.01596EPSS
SaveExploits0References1
CVE
CVE
•added 2020/04/22 6:15 p.m.•81 views

CVE-2020-7489

The CVE-2020-7489 issue affects Schneider Electric EcoStruxure Machine Expert – Basic or SoMachine Basic programming software. The root cause is CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component, enabling DLL substitution that could transfer malicious co...

9.8CVSS9.4AI score0.01596EPSS
SaveExploits0References1Affected Software2
Positive Technologies
Positive Technologies
•added 2020/04/22 12:00 a.m.•20 views

PT-2020-19607

Name of the Vulnerable Software and Affected Versions EcoStruxure Machine Expert – Basic or SoMachine Basic programming software affected versions not specified Description A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' issue exists, whi...

9.8CVSS7.3AI score0.01596EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/22 12:00 a.m.•5 views

CVE-2020-7489: Improper Neutralization of Special Elements in Output Used by a Downstream Component

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

9.8CVSS8.2AI score0.01596EPSS
SaveExploits0References4
OpenVAS
OpenVAS
•added 2019/01/31 12:00 a.m.•188 views

Schneider Electric EcoStruxure Machine Expert - HVAC Detection (Windows SMB Login)

SMB login-based detection of Schneider Electric EcoStruxure Machine Expert - HVAC. SPDX-FileCopyrightText: 2019 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescriptio...

7.1AI score
SaveExploits0References1
Rows per page
Query Builder