BDU FSTEC
BDU FSTEC
•added 2024/11/26 12:00 a.m.•26 views

SCALANCE M-800 Family Software Code Injection Rootkit

The vulnerability of microprogrammed software in industrial routers of the SCALANCE M-800 family including S615, MUM-800, and RM1224 is related to insufficient verification of input data. Exploiting this vulnerability allows a malicious actor to inject code into the root directory, thereby...

9CVSS7.5AI score0.00672EPSS
SaveExploits0References3Affected Software18
CNNVD
CNNVD
•added 2024/11/12 12:00 a.m.•25 views

Siemens RUGGEDCOM and Siemens SCALANCE have vulnerabilities in input validation.

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An input validation error vulnerability exists in multiple Siemens products and can be exploited by attackers to compromise system integrity...

4.3CVSS6.9AI score0.0028EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2024/11/12 12:00 a.m.•18 views

Siemens’ various products have security vulnerabilities

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An input validation error vulnerability exists in multiple Siemens products, which can be exploited by an attacker to execute arbitrary code on the device...

9.8CVSS7.8AI score0.00901EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2024/11/12 12:00 a.m.•10 views

PT-2024-8710

Name of the Vulnerable Software and Affected Versions RUGGEDCOM RM1224 LTE4G EU versions V8.2 RUGGEDCOM RM1224 LTE4G NAM versions V8.2 SCALANCE M804PB versions V8.2 SCALANCE M812-1 ADSL-Router versions V8.2 SCALANCE M816-1 ADSL-Router versions V8.2 SCALANCE M826-2 SHDSL-Router versions V8.2...

5.3CVSS6AI score0.00317EPSS
SaveExploits0References7
CNNVD
CNNVD
•added 2024/11/12 12:00 a.m.•24 views

Siemens’ various products have vulnerabilities related to access control.

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An access control error vulnerability exists in multiple Siemens products that can be exploited by an attacker to cause a temporary denial of service condition...

5.3CVSS6.7AI score0.00317EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2023/11/14 12:00 a.m.•17 views

Siemens SCALANCE security vulnerabilities

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.8CVSS7AI score0.00666EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2023/11/14 12:00 a.m.•21 views

Siemens SCALANCE security vulnerabilities

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.6CVSS7.7AI score0.00376EPSS
SaveExploits0References7
CNNVD
CNNVD
•added 2023/11/14 12:00 a.m.•27 views

Siemens SCALANCE injection vulnerability

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

9.4CVSS7.1AI score0.01341EPSS