NVD
NVD
•added 2025/01/17 11:15 a.m.•20 views

CVE-2024-10498

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in...

6.9CVSS0.00436EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/01/17 10:30 a.m.•5 views

CVE-2024-10498

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in...

6.9CVSS6.5AI score0.00436EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/01/17 10:30 a.m.•35 views

CVE-2024-10498

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in...

6.9CVSS0.00436EPSS
SaveExploits0References1
CVE
CVE
•added 2025/01/17 10:30 a.m.•68 views

CVE-2024-10498

Schneider Electric PowerLogic HDPM6000 is affected (CVE-2024-10498) by CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer. A memory-buffer bounds violation allows a remote attacker to modify configuration values outside the permitted range by sending specific Modbus ...

6.9CVSS6.5AI score0.00436EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/17 12:00 a.m.•10 views

Schneider Electric PowerLogic HDPM6000 缓冲区错误漏洞

The Schneider Electric PowerLogic HDPM6000 is a high density metering system from Schneider Electric France. A buffer error vulnerability exists in the Schneider Electric PowerLogic HDPM6000, which stems from the inclusion of a memory buffer in-bounds operationally unrestricted vulnerability that...

6.9CVSS6.6AI score0.00436EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/17 12:00 a.m.•2 views

CVE-2024-10498: Improper Restriction of Operations within the Bounds of a Memory Buffer

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in...

6.9CVSS5.9AI score0.00436EPSS
SaveExploits0References1
NVD
NVD
•added 2025/01/15 5:15 p.m.•24 views

CVE-2024-50953

An issue in XINJE XL5E-16T V3.7.2a allows attackers to cause a Denial of Service DoS via a crafted Modbus message...

7.5CVSS0.00425EPSS
SaveExploits0References1
NVD
NVD
•added 2025/01/15 5:15 p.m.•30 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

7.5CVSS0.00425EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/15 12:00 a.m.•12 views

XINJE XL5E-16T 安全漏洞

The XINJE XL5E-16T is an enhanced Ethernet controller from China XINJE Corporation XINJE. A security vulnerability exists in the XINJE XL5E-16T version 3.7.2a, which originated from a vulnerability that allows an attacker to cause a denial of service via a specially crafted Modbus message...

7.5CVSS6.5AI score0.00425EPSS
SaveExploits0References1
CVE
CVE
•added 2025/01/15 12:00 a.m.•88 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers, specifically versions V3.5.3b through V3.7.2a , are vulnerable to a flaw in Modbus message handling . If an attacker establishes a TCP connection within the local area network (LAN) and sends a specific Modbus message, they can cau...

6.7AI score0.00425EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/01/15 12:00 a.m.•7 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

6.9AI score0.00425EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•1 views

CVE-2024-50953: Uncontrolled Resource Consumption

An issue in XINJE XL5E-16T V3.7.2a allows attackers to cause a Denial of Service DoS via a crafted Modbus message...

7.5CVSS5.7AI score0.00425EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/01/15 12:00 a.m.•25 views

CVE-2024-50953

An issue in XINJE XL5E-16T V3.7.2a allows attackers to cause a Denial of Service DoS via a crafted Modbus message...

0.00425EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•1 views

CVE-2024-50954: Improper Check or Handling of Exceptional Conditions

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

7.5CVSS5.9AI score0.00425EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/01/15 12:00 a.m.•22 views

CVE-2024-50954

The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network LAN, sending a specific Modbus message to the controller can cau...

0.00425EPSS
SaveExploits0References1
CVE
CVE
•added 2025/01/15 12:00 a.m.•83 views

CVE-2024-50953

The XINJE XL5E-16T (an enhanced Ethernet controller by China XINJE Corporation) version 3.7.2a is susceptible to a Denial of Service (DoS) vulnerability. The root cause is an issue that allows an attacker to trigger a DoS condition by sending a specially crafted Modbus message . While the vulnera...

6.4AI score0.00425EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/15 12:00 a.m.•14 views

XINJE XL5E-16T和XINJE XD5E-24R-E 安全漏洞

XINJE XL5E-16T and XINJE XD5E-24R-E are both products of China XINJE Corporation XINJE.XINJE XL5E-16T is an enhanced Ethernet controller.XINJE XD5E-24R-E is an Ethernet controller. A security vulnerability exists in the XINJE XL5E-16T and XINJE XD5E-24R-E.5.3b through 3.7.2a versions, which stems...

7.5CVSS6.7AI score0.00425EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/01/15 12:00 a.m.•9 views

CVE-2024-50953

An issue in XINJE XL5E-16T V3.7.2a allows attackers to cause a Denial of Service DoS via a crafted Modbus message...

6.7AI score0.00425EPSS
SaveExploits0References1
NCSC
NCSC
•added 2024/12/13 9:58 a.m.•15 views

Vulnerability fixed in Schneider Electric Modicon

Schneider Electric has fixed a vulnerability in devices that use the Modbus protocol. The vulnerability is in how devices using the Modbus protocol validate input. When an unauthenticated and customized Modbus packet is sent to the device, it can result in a denial-of-service, compromising both t...

9.8CVSS7AI score0.00637EPSS
SaveExploits0References1
NVD
NVD
•added 2024/12/11 10:15 a.m.•37 views

CVE-2024-11737

CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of confidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device...

9.8CVSS0.00637EPSS
SaveExploits0References1