Lucene search
+L

1921 matches found

Prion
Prion
•added 2020/12/11 1:15 a.m.•29 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

5CVSS7.4AI score0.01338EPSS
SaveExploits0References1Affected Software16
Cvelist
Cvelist
•added 2020/12/11 12:52 a.m.•54 views

CVE-2020-7543

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5AI score0.01338EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/12/11 12:52 a.m.•43 views

CVE-2020-7542

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5AI score0.01338EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/12/11 12:51 a.m.•56 views

CVE-2020-7537

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5AI score0.01399EPSS
SaveExploits0References1
CVE
CVE
•added 2020/12/11 12:51 a.m.•111 views

CVE-2020-7537

CVE-2020-7537 affects Schneider Electric Modicon M580, M340, and legacy Quantum/Premium controllers. The root cause is an improper check for unusual or exceptional conditions (CWE-754) that can allow a remote attacker to trigger denial of service by sending a specially crafted Read Physical Memor...

7.5CVSS7.4AI score0.01399EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2020/12/11 12:00 a.m.•14 views

PT-2020-19620 · Schneider Electric · Modicon M580 +3

Name of the Vulnerable Software and Affected Versions: Modicon M580 affected versions not specified Modicon M340 affected versions not specified Legacy Controllers Modicon Quantum affected versions not specified Legacy Controllers Modicon Premium affected versions not specified Description: A...

7.5CVSS7.3AI score0.01338EPSS
SaveExploits0References19
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/11 12:00 a.m.•2 views

CVE-2020-7543: Improper Check for Unusual or Exceptional Conditions

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5CVSS5.8AI score0.01338EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/12/11 12:00 a.m.•11 views

PT-2020-19621 · Schneider Electric · Modicon M580 +3

Name of the Vulnerable Software and Affected Versions: Modicon M580 affected versions not specified Modicon M340 affected versions not specified Legacy Controllers Modicon Quantum affected versions not specified Legacy Controllers Modicon Premium affected versions not specified Description: A...

7.5CVSS7.3AI score0.01338EPSS
SaveExploits0References21
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/11 12:00 a.m.•5 views

CVE-2020-7537: Improper Check for Unusual or Exceptional Conditions

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5CVSS5.8AI score0.01399EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/11 12:00 a.m.•2 views

CVE-2020-7542: Improper Check for Unusual or Exceptional Conditions

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...

7.5CVSS5.8AI score0.01338EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/12/08 12:00 a.m.•19 views

PT-2020-6372 · Schneider Electric · Modicon M580 +3

Name of the Vulnerable Software and Affected Versions: Modicon M580 affected versions not specified Modicon M340 affected versions not specified Legacy Controllers Modicon Quantum affected versions not specified Modicon Premium affected versions not specified Description: A vulnerability exists...

7.8CVSS7.3AI score0.01399EPSS
SaveExploits0References28
Talos
Talos
•added 2020/12/08 12:00 a.m.•254 views

Schneider Electric EcoStruxure Control Expert PLC Simulator Modbus message processing remote code execution vulnerability

Summary A code execution vulnerability exists in the Modbus message-processing functionality of Schneider Electric EcoStruxure Control Expert PLC Simulator 14.1. A specially crafted network request can lead to remote code execution. An attacker can send a large Modbus request to trigger this...

7.5CVSS8.1AI score0.01905EPSS
SaveExploits1
BDU FSTEC
BDU FSTEC
•added 2020/12/07 12:00 a.m.•14 views

The vulnerability of the Modbus terminal protocol implementation in the EKRA 200 microprocessor series allows a hacker to execute any Modbus command and alter the controller’s configuration, including modifying the control program and executing arbitrary code.

The vulnerability of the Modbus microprogramming software for ECUs exists due to the lack of authentication for any Modbus protocol commands. Exploiting this vulnerability allows a malicious actor to execute any Modbus command remotely and alter the controller’s configuration, including modifying...

10CVSS5.8AI score
SaveExploits0References1Affected Software1
Prion
Prion
•added 2020/12/04 8:15 a.m.•20 views

Design/Logic Flaw

Out-of-bounds read vulnerability in GT21 model of GOT2000 series GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier, GS21 model of GOT series GS2110-WTBD V01.39.000...

5CVSS7.4AI score0.0282EPSS
SaveExploits0References3Affected Software10
CNNVD
CNNVD
•added 2020/12/01 12:00 a.m.•18 views

Multiple Schneider Electric Product Security Feature Issue Vulnerabilities

Schneider Electric Acti9 Smartlink SI D is a smart interface unit that realizes data communication between Acti9 electrical devices and Modbus devices. Schneider Electric Acti9 Smartlink SI D is an intelligent interface unit that enables data communication between Acti9 electrical devices and...

9.8CVSS7.3AI score0.01444EPSS
SaveExploits0References2
CNVD
CNVD
•added 2020/11/20 12:00 a.m.•39 views

Unspecified Vulnerability in Schneider Electric EcoStruxure Control Expert

EcoStruxure Control Expert is the universal programming, debugging and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A security vulnerability exists in PLC Simulator in EcoStruxure Control Expert. The vulnerability can be exploited by an attacker to...

9.8CVSS7.2AI score0.02757EPSS
SaveExploits0References1
CNVD
CNVD
•added 2020/11/20 12:00 a.m.•55 views

Schneider Electric EcoStruxure Control Expert Command Execution Vulnerability

Schneider Electric EcoStruxure Control Expert is the universal programming, commissioning and operating software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum series. A command execution vulnerability exists in Schneider Electric EcoStruxure Control Expert. The vulnerability...

8.8CVSS7.3AI score0.01178EPSS
SaveExploits0References1
NVD
NVD
•added 2020/11/19 10:15 p.m.•41 views

CVE-2020-7559

A CWE-120: Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially...

7.5CVSS7.5AI score0.01905EPSS
SaveExploits1References2
NVD
NVD
•added 2020/11/19 10:15 p.m.•39 views

CVE-2020-7538

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request...

7.5CVSS7.5AI score0.01288EPSS
SaveExploits0References1
NVD
NVD
•added 2020/11/19 10:15 p.m.•43 views

CVE-2020-28213

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert now Unity Pro all versions that could cause unauthorized command execution when sending specially crafted requests over Modbus...

8.8CVSS8.9AI score0.01178EPSS
SaveExploits0References1
Rows per page
Query Builder