Zero Science Lab
Zero Science Lab
added 2021/09/08 12:00 a.m.218 views

ECOA Building Automation System Path Traversal Arbitrary File Upload

Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...

10CVSS7.8AI score0.02322EPSS
SaveExploits1
OSV
OSV
added 2021/08/05 9:15 p.m.9 views

CVE-2021-20592

Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...

7.5CVSS5.8AI score0.01497EPSS
SaveExploits0References2
NVD
NVD
added 2021/08/05 9:15 p.m.35 views

CVE-2021-20592

Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...

7.8CVSS0.01497EPSS
SaveExploits0References2
Prion
Prion
added 2021/08/05 9:15 p.m.29 views

Design/Logic Flaw

Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...

7.8CVSS7.5AI score0.01497EPSS
SaveExploits0References2Affected Software4
CVE
CVE
added 2021/08/05 8:46 p.m.106 views

CVE-2021-20592

CVE-2021-20592 affects Mitsubishi Electric GOT2000 family: GOT2000 GT27/GT25/GT23 MODBUS/TCP Slave drivers (versions 01.19.000–01.39.010) and GT SoftGOT2000 (versions 1.170C–1.256S). Root cause is missing synchronization in the MODBUS/TCP communication path, allowing a remote unauthenticated atta...

7.8CVSS7.5AI score0.01497EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2021/08/05 8:46 p.m.64 views

CVE-2021-20592

Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...

7.7AI score0.01497EPSS
SaveExploits0References2
CNVD
CNVD
added 2021/08/05 12:00 a.m.62 views

Unspecified Vulnerability in Siemens Interniche IP Stack Low Voltage Devices

The SENTRON 3WA COM190 is an accessory module for 3WA circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 3WL COM35 is an accessory module for 3WL circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 7KM PAC The Switched Ethernet PROFIN...

9.1CVSS9.2AI score0.02051EPSS
SaveExploits0References1
ICS
ICS
added 2021/07/27 12:00 a.m.257 views

Mitsubishi Electric GOT2000 series and GT SoftGOT2000

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: GOT2000 series and GT SoftGOT2000 Vulnerability: Missing Synchronization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service...

7.8CVSS7.6AI score0.01497EPSS
SaveExploits0References5
NVD
NVD
added 2021/06/11 4:15 p.m.29 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.3CVSS0.01874EPSS
SaveExploits0References2
OSV
OSV
added 2021/06/11 4:15 p.m.10 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.3CVSS6.1AI score0.01874EPSS
SaveExploits0References2
Prion
Prion
added 2021/06/11 4:15 p.m.17 views

Authentication flaw

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5CVSS5.3AI score0.01874EPSS
SaveExploits0References1Affected Software4
CVE
CVE
added 2021/06/11 3:40 p.m.68 views

CVE-2021-22764

CVE-2021-22764 is an improper authentication vulnerability affecting Schneider Electric PowerLogic PM55xx, PM8ECC, EGX100, and EGX300. The issue can cause loss of connectivity to the device over Modbus TCP when an attacker sends a specially crafted HTTP request. Public documents identify the affe...

5.3CVSS5.3AI score0.01874EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2021/06/11 3:40 p.m.39 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.6AI score0.01874EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2021/06/11 12:00 a.m.19 views

PT-2021-15202

Name of the Vulnerable Software and Affected Versions PowerLogic PM55xx affected versions not specified PowerLogic PM8ECC affected versions not specified PowerLogic EGX100 affected versions not specified PowerLogic EGX300 affected versions not specified Description A CWE-287: Improper...

5.3CVSS6.1AI score0.01874EPSS
SaveExploits0References6
NVD
NVD
added 2021/05/19 11:15 a.m.70 views

CVE-2021-20589

Buffer access with incorrect length value vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.38.000, GT25 model communication driver versions 01.19.000 through 01.38.000, GT23 model communication driver versions 01.19.000 through 01.38.000 and GT21 model...

7.5CVSS0.01476EPSS
SaveExploits0References2
OSV
OSV
added 2021/05/19 11:15 a.m.6 views

CVE-2021-20589

Buffer access with incorrect length value vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.38.000, GT25 model communication driver versions 01.19.000 through 01.38.000, GT23 model communication driver versions 01.19.000 through 01.38.000 and GT21 model...

7.5CVSS5.8AI score0.01476EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2021/05/19 10:28 a.m.56 views

CVE-2021-20589

Buffer access with incorrect length value vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.38.000, GT25 model communication driver versions 01.19.000 through 01.38.000, GT23 model communication driver versions 01.19.000 through 01.38.000 and GT21 model...

7.8AI score0.01476EPSS
SaveExploits0References2
ICS
ICS
added 2021/05/11 12:00 a.m.65 views

Mitsubishi Electric GOT and Tension Controller (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: GOT and Tension Controller Vulnerability: Buffer Access with Incorrect Length Value 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-131-02...

7.5CVSS7.6AI score0.01476EPSS
SaveExploits0References4
ICS
ICS
added 2021/02/02 12:00 a.m.78 views

Rockwell Automation MicroLogix 1400 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: MicroLogix 1400 Vulnerability: Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-033-01 Rockwell Automation MicroLogix 1400 that...

8.6CVSS9AI score0.01719EPSS
SaveExploits0References5
Prion
Prion
added 2020/12/04 8:15 a.m.16 views

Design/Logic Flaw

Out-of-bounds read vulnerability in GT21 model of GOT2000 series GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier, GS21 model of GOT series GS2110-WTBD V01.39.000...

5CVSS7.4AI score0.02786EPSS
SaveExploits0References3Affected Software10