453 matches found
UVI-2021-1000396 KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit
KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit This is an automated ID intended to aid in discovery of potential security vulnerabilities. The actual impact and attack plausibility have not yet been proven. This ID is fixed in Linux Kernel version v5.10.37 by commit...
GSD-2021-1000396 KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit
KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit This is an automated ID intended to aid in discovery of potential security vulnerabilities. The actual impact and attack plausibility have not yet been proven. This ID is fixed in Linux Kernel version v5.10.37 by commit...
GSD-2021-1000300 KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit
KVM: x86/mmu: Alloc page for PDPTEs when shadowing 32-bit NPT with 64-bit This is an automated ID intended to aid in discovery of potential security vulnerabilities. The actual impact and attack plausibility have not yet been proven. This ID is fixed in Linux Kernel version v5.12.4 by commit...
OSV-2020-2180 UNKNOWN READ in helper_be_stl_mmu_armeb
OSS-Fuzz report: https://bugs.chromium.org/p/oss-fuzz/issues/detail?id=27736 Crash type: UNKNOWN READ Crash state: helperbestlmmuarmeb stack...
Siemens SICAM MMU, SGU and T Cross-Site Scripting Vulnerabilities (CNVD-2020-40616)
SICAM T is a digital measurement sensor that allows the measurement of power in the non-electrical network in a single unit.ICAM-MMU Measurement and Monitoring Unit is a power monitoring unit that allows the measurement of power in the grid in a single unit.SICAM SGU Discontinued is a Smart Grid...
Siemens SICAM MMU, SGU and T Out-of-Bounds Read Vulnerabilities
SICAM T is a digital measurement sensor that allows the measurement of power in the non-electrical network in a single unit.ICAM-MMU Measurement and Monitoring Unit is a power monitoring unit that allows the measurement of power in the grid in a single unit.SICAM SGU Discontinued is a Smart Grid...
CVE-2020-10044
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device...
CVE-2020-10045
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application...
CVE-2020-10044
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device...
CVE-2020-10045
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application...
CVE-2020-10040
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with local access to the device might be able to retrieve some passwords in clear text...
CVE-2020-10041
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. A stored Cross-Site-Scripting XSS vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user...
CVE-2020-10037
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information...
CVE-2020-10038
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the device's web server might be able to execute administrative commands without authentication...
CVE-2020-10041
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. A stored Cross-Site-Scripting XSS vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user...
CVE-2020-10042
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network...
CVE-2020-10039
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to...
CVE-2020-10043
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. The web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked into accessing a malicious link...
CVE-2020-10040
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with local access to the device might be able to retrieve some passwords in clear text...
CVE-2020-10037