Lucene search
+L

1848 matches found

Positive Technologies
Positive Technologies
added 2019/11/18 12:00 a.m.14 views

PT-2019-4283 · Apache +1 · Apache Shiro +1

Name of the Vulnerable Software and Affected Versions: Apache Shiro versions prior to 1.4.2 Description: The issue is related to the use of the default "remember me" configuration in Apache Shiro, which can make cookies susceptible to a padding attack. This could allow a remote attacker to impact...

7.5CVSS7.5AI score0.09101EPSS
SaveExploits0References18
CNVD
CNVD
added 2019/11/04 12:00 a.m.7 views

Unspecified Vulnerability in Mitsubishi Electric smartRTUs and Inea ME-RTUs

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A security vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA ME-RTU version...

6.5CVSS6.6AI score0.0126EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/11/04 12:00 a.m.11 views

Mitsubishi Electric smartRTU and Inea ME-RTU Information Disclosure Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A security vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA ME-RTU version...

7.5CVSS7AI score0.41847EPSS
SaveExploits3References1
CNVD
CNVD
added 2019/10/31 12:00 a.m.11 views

Mitsubishi Electric smartRTU and Inea ME-RTU Password Plaintext Storage Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A password plaintext storage vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and...

9.8CVSS7.2AI score0.01936EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/10/31 12:00 a.m.8 views

Mitsubishi Electric smartRTU and Inea ME-RTU Cross-Site Scripting Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A cross-site scripting vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA...

5.4CVSS6.4AI score0.44149EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/10/31 12:00 a.m.12 views

Mitsubishi Electric smartRTU and Inea ME-RTU Trust Management Issue Vulnerability (CNVD-2019-47031)

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A trust management issue vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA...

10CVSS6.9AI score0.02343EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/10/29 12:00 a.m.9 views

Mitsubishi Electric smartRTU and Inea ME-RTU Trust Management Issue Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A trust management issue vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA...

9.8CVSS7AI score0.02085EPSS
SaveExploits1References1
NVD
NVD
added 2019/10/28 1:15 p.m.26 views

CVE-2019-14931

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...

10CVSS10AI score0.5809EPSS
SaveExploits3References2
OSV
OSV
added 2019/10/28 1:15 p.m.11 views

CVE-2019-14931

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...

9.8CVSS7.6AI score0.5809EPSS
SaveExploits3References2
OSV
OSV
added 2019/10/28 1:15 p.m.5 views

CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...

9.8CVSS7.3AI score0.02343EPSS
SaveExploits1References2
NVD
NVD
added 2019/10/28 1:15 p.m.28 views

CVE-2019-14927

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames,...

7.5CVSS8.1AI score0.41847EPSS
SaveExploits3References2
OSV
OSV
added 2019/10/28 1:15 p.m.7 views

CVE-2019-14927

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames,...

7.5CVSS7.2AI score0.41847EPSS
SaveExploits3References2
NVD
NVD
added 2019/10/28 1:15 p.m.34 views

CVE-2019-14926

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with...

9.8CVSS9.7AI score0.02085EPSS
SaveExploits1References2
OSV
OSV
added 2019/10/28 1:15 p.m.7 views

CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...

5.4CVSS6.1AI score0.44149EPSS
SaveExploits1References2
NVD
NVD
added 2019/10/28 1:15 p.m.28 views

CVE-2019-14929

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management ...

9.8CVSS9.7AI score0.01936EPSS
SaveExploits1References2
NVD
NVD
added 2019/10/28 1:15 p.m.28 views

CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...

6.5CVSS7.1AI score0.0126EPSS
SaveExploits1References2
NVD
NVD
added 2019/10/28 1:15 p.m.69 views

CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...

5.4CVSS6.4AI score0.44149EPSS
SaveExploits1References2
NVD
NVD
added 2019/10/28 1:15 p.m.27 views

CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...

10CVSS9.9AI score0.02343EPSS
SaveExploits1References2
Prion
Prion
added 2019/10/28 1:15 p.m.28 views

Design/Logic Flaw

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and othe...

4CVSS7AI score0.0126EPSS
SaveExploits1References2Affected Software2
Prion
Prion
added 2019/10/28 1:15 p.m.25 views

Default credentials

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. ...

5CVSS9.6AI score0.01936EPSS
SaveExploits1References2Affected Software2
Rows per page
Query Builder