639 matches found
Default FTP Credentials (ntpupdate / ntpupdate)
It is possible to log into the remote FTP server by providing default credentials. A remote attacker could exploit this to gain access to the remote server. These credentials are known to apply to Schneider Electric Modicon M340 for Ethernet devices; however, they may apply to other FTP services ...
Schneider Electric Modicon M340 Detection (HTTP)
HTTP based detection of Schneider Electric Modicon M340 devices. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...
Schneider Modicon M340 Device Default Credentials (HTTP)
The remote Schneider Modicon M340 device is using known default credentials. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only CPE =...
PT-2013-1323 · Schneider Electric · Modicon M340 +2
Name of the Vulnerable Software and Affected Versions: Modicon M340 versions affected versions not specified Modicon Quantum versions affected versions not specified Modicon Premium versions affected versions not specified Description: The issue is related to errors in security mechanisms, which...
CVE-2013-2763
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service resource consumption via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny...
CVE-2013-2761
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service module crash via crafted FTP traffic, as demonstrated by the FileZilla FTP client...
CVE-2013-0664
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests...
Code injection
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests...
Design/Logic Flaw
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service module crash via crafted FTP traffic, as demonstrated by the FileZilla FTP client...
Design/Logic Flaw
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service resource consumption via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny...
CVE-2013-0663
Cross-site request forgery CSRF vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary...
CVE-2013-2763
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service resource consumption via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny...
CVE-2013-2761
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service module crash via crafted FTP traffic, as demonstrated by the FileZilla FTP client...
CVE-2013-0663
CVE-2013-0663 affects Schneider Electric Modicon M340, Quantum 140NOE7711x/140NWM10000, and Premium TSXETY4103/5103/TSXWMY100 PLC modules. The vulnerability is a Cross-Site Request Forgery (CSRF) in the web server interface that permits remote attackers to hijack user authentication and issue com...
CVE-2013-2761
Summary: CVE-2013-2761 affects Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules. Vulnerability: Remote authenticated users can trigger a denial of service (module crash) by sending crafted FTP traffic (as demonstrated with FileZilla). Impact: Partial availability loss of the affected...
CVE-2013-2763
Summary (CVE-2013-2763) : The Schneider Electric M340 PLC modules are reported to be susceptible to a remote denial-of-service (resource consumption) via unspecified vectors. The vendor disputes the issue, stating it could not be duplicated and that the observed behavior could not remotely deny P...
CVE-2013-0664
CVE-2013-0664 affects Schneider Electric Modicon PLCs (Quantum 140NOE77111, 140NWM10000, M340 BMXNOE0110x, Premium TSXETY5103). The vulnerability arises in the FactoryCast feature: remote authenticated users can embed Modbus messages in SOAP HTTP POST requests, enabling arbitrary code execution o...
PT-2013-3916 · Schneider Electric · Schneider Electric M340
Name of the Vulnerable Software and Affected Versions: Schneider Electric M340 PLC modules affected versions not specified Description: The issue allows remote attackers to cause a denial of service through resource consumption via unspecified vectors. The vendor reportedly disputes this issue,...
CVE-2011-4859
CVE-2011-4859 concerns the Schneider Electric Quantum Ethernet Module family, where hard-coded credentials exist for 16 accounts (AUTCSE, AUT_CSE, fdrusers, ftpuser, loader, nic2212, nimrohs2212, nip2212, noe77111_v500, ntpupdate, pcfactory, sysdiag, target, test, USER, webserver). This enables r...