Lucene search
+L

144 matches found

Kitploit
Kitploit
•added 2026/10/13 1:46 a.m.•23 views

CVE-2026-58457

CVE-2026-58457 - Unauthenticated OS Command Injection in Shenzhen Aitemi M300 Wi-Fi Repeater !WARNING This code is provided AS IS for educational and research purposes only. Do not use this PoC on production systems, shared environments, or any unauthorized targets. Running or hosting this code m...

9.8CVSS6.5AI score0.02939EPSS
SaveExploits1References1
Kitploit
Kitploit
•added 2026/10/12 11:22 p.m.•21 views

CVE-2025-34152

⚠️ CVE-2025-34152 – Shenzhen Aitemi M300 Wi-Fi Repeater RCE 🚨 Overview Shenzhen Aitemi M300 Wi-Fi Repeater is affected by an unauthenticated remote code execution RCE. No login required Does not reboot the device Can be exploited remotely 🛠 Vulnerable Versions Version| Status ---|--- 1.0.x| ❌...

9.4CVSS8.5AI score0.86839EPSS
SaveExploits5
VulnCheck KEV
VulnCheck KEV
•added 2026/09/04 12:00 a.m.•19 views

VulnCheck KEV: CVE-2026-58457

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.6AI score0.02939EPSS
SaveIn wildExploits1References10
NVD
NVD
•added 2026/08/09 11:16 a.m.•24 views

CVE-2026-19348

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS0.03568EPSS
SaveExploits0References7
CVE
CVE
•added 2026/08/09 10:30 a.m.•109 views

CVE-2026-19348

The CVE-2026-19348 entry concerns Shenzhen Aitemi M300 Wi‑Fi Repeater. A vulnerability in the sprintf handling within /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add&name=test&enable=1 allows remote command injection by manipulating parameters such as enable/name/mac. Impact is h...

10CVSS7.9AI score0.03568EPSS
SaveExploits0References7
attackerkb
attackerkb
•added 2026/08/09 10:30 a.m.•22 views

CVE-2026-19348

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS7.9AI score0.03568EPSS
SaveExploits0References7
Vulnrichment
Vulnrichment
•added 2026/08/09 10:30 a.m.•17 views

CVE-2026-19348 Shenzhen Aitemi M300 Wi-Fi Repeater protocol.csp sprintf command injection

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS7.9AI score0.03568EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/09 12:00 a.m.•8 views

CVE-2026-19348: Improper Neutralization of Special Elements used in a Command

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS7.9AI score0.03568EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/09 12:00 a.m.•8 views

PT-2026-69290

Name of the Vulnerable Software and Affected Versions Shenzhen Aitemi M300 Wi-Fi Repeater version r0-ea7890a Description A remote command injection flaw exists due to improper handling of arguments in the sprintf function within the /protocol.csp?fname=net&opt=smacfilter...

10CVSS6AI score0.03568EPSS
SaveExploits0References10
GithubExploit
GithubExploit
•added 2026/07/16 10:53 p.m.•105 views

Exploit for CVE-2026-58457

CVE-2026-58457 - Unauthenticated OS Command Injection in Shenz...

9.8CVSS6.2AI score0.02939EPSS
SaveExploits1
Vulnrichment
Vulnrichment
•added 2026/07/01 7:22 p.m.•17 views

CVE-2026-58457 Shenzhen Aitemi M300 MT02 Unauthenticated OS Command Injection via protocol.csp

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.6AI score0.02939EPSS
SaveExploits1References3
attackerkb
attackerkb
•added 2026/07/01 7:22 p.m.•23 views

CVE-2026-58457

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.6AI score0.02939EPSS
SaveExploits1References4
CVE
CVE
•added 2026/07/01 7:22 p.m.•92 views

CVE-2026-58457

The Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) is vulnerable to an unauthenticated OS command injection in the commuos web backend . The root cause is the lack of input sanitization in the smacfilter_conf handler, where the name , enable , and mac GET parameters are passed directly...

9.8CVSS6.6AI score0.02939EPSS
SaveIn wildExploits1References3
Positive Technologies
Positive Technologies
•added 2026/07/01 12:00 a.m.•36 views

PT-2026-54917

Name of the Vulnerable Software and Affected Versions Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 affected versions not specified Description An unauthenticated OS command injection exists in the commuos web backend. Network-adjacent attackers can execute arbitrary shell commands by...

9.8CVSS6.3AI score0.02939EPSS
SaveExploits1References12
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/07/01 12:00 a.m.•8 views

CVE-2026-58457: Improper Neutralization of Special Elements used in an OS Command

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.6AI score0.02939EPSS
SaveExploits1References2
NVD
NVD
•added 2026/06/02 8:16 p.m.•32 views

CVE-2019-25724

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
SaveExploits0References2
NVD
NVD
•added 2026/06/02 8:16 p.m.•38 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00187EPSS
SaveExploits0References2
EUVD
EUVD
•added 2026/06/02 7:11 p.m.•31 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2026/06/02 7:11 p.m.•14 views

CVE-2019-25724

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2026/06/02 7:11 p.m.•57 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
SaveExploits0References2
Rows per page