Lucene search
+L

126 matches found

Kitploit
Kitploit
added 2026/09/22 2:11 p.m.12 views

CVE-2025-34152

⚠️ CVE-2025-34152 – Shenzhen Aitemi M300 Wi-Fi Repeater RCE 🚨 Overview Shenzhen Aitemi M300 Wi-Fi Repeater is affected by an unauthenticated remote code execution RCE. No login required Does not reboot the device Can be exploited remotely 🛠 Vulnerable Versions...

9.4CVSS8.4AI score0.68599EPSS
SaveExploits5
Kitploit
Kitploit
added 2026/09/22 1:45 a.m.13 views

CVE-2026-58457

CVE-2026-58457 - Unauthenticated OS Command Injection in Shenzhen Aitemi M300 Wi-Fi Repeater !WARNING This code is provided AS IS for educational and research purposes only. Do not use this PoC on production systems, shared environments, or any unauthorized targets. Running or hosting this code m...

9.8CVSS6AI score0.02939EPSS
SaveExploits1
VulnCheck KEV
VulnCheck KEV
added 2026/09/04 12:00 a.m.12 views

VulnCheck KEV: CVE-2026-58457

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS5.8AI score0.02939EPSS
SaveIn wildExploits1References10
NVD
NVD
added 2026/08/09 11:16 a.m.16 views

CVE-2026-19348

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS0.01973EPSS
SaveExploits0References7
CVE
CVE
added 2026/08/09 10:30 a.m.96 views

CVE-2026-19348

The CVE-2026-19348 entry concerns Shenzhen Aitemi M300 Wi‑Fi Repeater. A vulnerability in the sprintf handling within /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add&name=test&enable=1 allows remote command injection by manipulating parameters such as enable/name/mac. Impact is h...

10CVSS8.3AI score0.01973EPSS
SaveExploits0References7
Vulnrichment
Vulnrichment
added 2026/08/09 10:30 a.m.9 views

CVE-2026-19348 Shenzhen Aitemi M300 Wi-Fi Repeater protocol.csp sprintf command injection

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS8.4AI score0.01973EPSS
SaveExploits0References7
attackerkb
attackerkb
added 2026/08/09 10:30 a.m.15 views

CVE-2026-19348

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilterconf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command...

10CVSS5.3AI score0.01973EPSS
SaveExploits0References7
GithubExploit
GithubExploit
added 2026/07/16 10:53 p.m.99 views

Exploit for CVE-2026-58457

CVE-2026-58457 - Unauthenticated OS Command Injection in Shenz...

9.8CVSS6.2AI score0.02939EPSS
SaveExploits1
CVE
CVE
added 2026/07/01 7:22 p.m.80 views

CVE-2026-58457

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.1AI score0.02939EPSS
SaveIn wildExploits1References3
attackerkb
attackerkb
added 2026/07/01 7:22 p.m.16 views

CVE-2026-58457

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.1AI score0.02939EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2026/07/01 7:22 p.m.15 views

CVE-2026-58457 Shenzhen Aitemi M300 MT02 Unauthenticated OS Command Injection via protocol.csp

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS6.2AI score0.02939EPSS
SaveExploits1References3
Positive Technologies
Positive Technologies
added 2026/07/01 12:00 a.m.29 views

PT-2026-54917

Name of the Vulnerable Software and Affected Versions Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 affected versions not specified Description An unauthenticated OS command injection exists in the commuos web backend. Network-adjacent attackers can execute arbitrary shell commands by...

9.8CVSS6AI score0.02939EPSS
SaveExploits1References12
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
added 2026/07/01 12:00 a.m.4 views

CVE-2026-58457: Improper Neutralization of Special Elements used in an OS Command

Shenzhen Aitemi M300 Wi-Fi Repeater hardware model MT02 contains an unauthenticated OS command injection vulnerability that allows network-adjacent attackers to execute arbitrary shell commands by injecting unsanitized input through the smacfilterconf handler in the commuos web backend. Attackers...

9.8CVSS0.02939EPSS
SaveExploits1References2
NVD
NVD
added 2026/06/02 8:16 p.m.32 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00187EPSS
SaveExploits0References2
NVD
NVD
added 2026/06/02 8:16 p.m.28 views

CVE-2019-25724

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
SaveExploits0References2
CVE
CVE
added 2026/06/02 7:11 p.m.51 views

CVE-2019-25724

The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/06/02 7:11 p.m.12 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2026/06/02 7:11 p.m.52 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
SaveExploits0References2
attackerkb
attackerkb
added 2026/06/02 7:11 p.m.10 views

CVE-2019-25724

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References4
EUVD
EUVD
added 2026/06/02 7:11 p.m.28 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
Rows per page
Query Builder