Lucene search
+L

41 matches found

NVD
NVD
added 2020/04/22 7:15 p.m.16 views

CVE-2020-7488

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers...

7.5CVSS7.4AI score0.00855EPSS
SaveExploits0References1
Prion
Prion
added 2020/04/22 7:15 p.m.16 views

Design/Logic Flaw

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers...

7.5CVSS9.4AI score0.00675EPSS
SaveExploits0References1
Prion
Prion
added 2020/04/22 7:15 p.m.14 views

Design/Logic Flaw

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers...

5CVSS7.3AI score0.00855EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2020/04/22 6:51 p.m.6 views

CVE-2020-7488

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers...

7.1AI score0.00855EPSS
SaveExploits0References1
CVE
CVE
added 2020/04/22 6:51 p.m.53 views

CVE-2020-7488

The CVE-2020-7488 issue concerns a CWE-319 vulnerability (Cleartext Transmission of Sensitive Information) that could leak sensitive data transmitted between Schneider Electric’s Modicon controllers (M218, M241, M251, M258) and associated software. The root cause is insecure cleartext transmissio...

7.5CVSS7.3AI score0.00855EPSS
SaveExploits0References1Affected Software3
Prion
Prion
added 2019/05/22 8:29 p.m.27 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

6.4CVSS8.1AI score0.0125EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2019/05/22 7:40 p.m.43 views

CVE-2019-6820

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

8.2AI score0.0125EPSS
SaveExploits0References1
CVE
CVE
added 2019/05/22 7:40 p.m.96 views

CVE-2019-6820

CVE-2019-6820 describes a CWE-306 vulnerability (Missing Authentication for a Critical Function) that could allow modification of device IP configuration (IP address, netmask, gateway) when a specific Ethernet frame is received on multiple Schneider Electric Modicon/drive products. Affected produ...

8.2CVSS8.1AI score0.0125EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
added 2019/05/14 12:0 a.m.9 views

PT-2019-2282

Name of the Vulnerable Software and Affected Versions Modicon M100 versions all Modicon M200 versions all Modicon M221 versions all ATV IMC drive controller versions all Modicon M241 versions all Modicon M251 versions all Modicon M258 versions all Modicon LMC058 versions all Modicon LMC078 versio...

8.2CVSS7.3AI score0.0125EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2019/05/13 12:0 a.m.13 views

Schneider Electric Modicon M241 PLC Detection

Binary data 252.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/13 12:0 a.m.13 views

Schneider Electric Modicon M241 or M251 PLC Detection

Binary data 755296.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.12 views

Schneider Electric Modicon M241 and M251 PLCs Insufficiently Random Values

Binary data 720114.prm...

9.1CVSS7.3AI score0.3182EPSS
SaveExploits5References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.9 views

Schneider Electric Modicon M241 and M251 PLCs Insufficiently Protected Credentials

Binary data 720115.prm...

9.8CVSS7.3AI score0.0225EPSS
SaveExploits0References2
NVD
NVD
added 2017/06/30 3:29 a.m.13 views

CVE-2017-6026

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...

9.1CVSS9.2AI score0.3182EPSS
SaveExploits5References3
OSV
OSV
added 2017/06/30 3:29 a.m.4 views

CVE-2017-6026

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...

9.1CVSS5.8AI score0.3182EPSS
SaveExploits5References3
OSV
OSV
added 2017/06/30 3:29 a.m.3 views

CVE-2017-6030

A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...

6.5CVSS5.8AI score0.02142EPSS
SaveExploits0References2
Prion
Prion
added 2017/06/30 3:29 a.m.17 views

Design/Logic Flaw

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...

5CVSS9.3AI score0.0225EPSS
SaveExploits0References2Affected Software2
OSV
OSV
added 2017/06/30 3:29 a.m.8 views

CVE-2017-6028

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...

9.8CVSS5.8AI score0.0225EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2017/06/30 2:35 a.m.4 views

CVE-2017-6030 Schneider Electric Modicon PLCs Predictable Value Range from Previous Values

A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...

6.5AI score0.02142EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2017/06/30 2:35 a.m.23 views

CVE-2017-6026

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...

9.1AI score0.3182EPSS
SaveExploits5References3
Rows per page