Lucene search
+L

169 matches found

CVE
CVE
added 2020/11/19 9:10 p.m.77 views

CVE-2020-7567

CVE-2020-7567 targets Schneider Electric Modicon M221 PLCs. A missing encryption of sensitive data vulnerability could allow an attacker who captures traffic between EcoStruxure Machine-Basic software and the M221 controller to break encryption keys and obtain password hashes. Affected: Modicon M...

7.1CVSS5.5AI score0.00206EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2020/11/19 9:10 p.m.78 views

CVE-2020-7566

CVE-2020-7566 (Modicon M221) is a reported issue: a CWE-334 Small Space of Random Values vulnerability that could allow an attacker who captures traffic between EcoStruxure Machine - Basic software and the Modicon M221 controller to break encryption keys. Affected product: Schneider Electric Modi...

7.3CVSS7AI score0.00296EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2020/11/19 9:10 p.m.9 views

CVE-2020-7566

A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller...

7.1AI score0.00296EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/11/19 9:10 p.m.41 views

CVE-2020-7566

A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller...

7.1AI score0.00296EPSS
SaveExploits0References2
CVE
CVE
added 2020/11/19 9:10 p.m.87 views

CVE-2020-7565

CVE-2020-7565 affects Schneider Electric Modicon M221 PLCs (all versions) and is about Inadequate Encryption Strength (CWE-326). The root cause is weakness in cryptographic protection that could allow an attacker to break the encryption key when intercepting traffic between EcoStruxure Machine - ...

7.3CVSS7AI score0.00296EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2020/11/19 9:10 p.m.8 views

CVE-2020-7565

A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller...

7.1AI score0.00296EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/11/19 9:10 p.m.44 views

CVE-2020-7565

A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller...

7.1AI score0.00296EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2020/11/19 12:00 a.m.12 views

Schneider Electric Modicon M221 Information Disclosure Vulnerability

The Schneider Electric Modicon M221 is a programmable logic controller from Schneider Electric, France. The Modicon M221 suffers from an information disclosure vulnerability that originates from the presence of a sensitive information exposure to an unauthorized Actor vulnerability that can be...

4.3CVSS5.8AI score0.00527EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2020/11/19 12:00 a.m.12 views

Schneider Electric Modicon M221 Security Breach

The Schneider Electric Modicon M221 is a programmable logic controller from Schneider Electric, France. The Modicon M221 suffers from a security vulnerability that stems from a sensitive data vulnerability encryption gap that can be exploited by an attacker to find a password hash after capturing...

5.7CVSS6.2AI score0.00206EPSS
SaveExploits0References3
ThreatPost
ThreatPost
added 2020/11/12 4:52 p.m.22 views

Bugs in Critical Infrastructure Gear Allow Sophisticated Cyberattacks

Two security vulnerabilities in Schneider Electric’s programmable logic controllers PLCs could allow attackers to compromise a PLC and move on to more sophisticated critical infrastructure attacks. PLCs are key pieces of equipment in environments such as electric utilities and factories. They...

0.4AI score
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2020/11/10 12:00 a.m.18 views

PT-2020-6349

Name of the Vulnerable Software and Affected Versions Modicon M221 all references, all versions Modicon M100 affected versions not specified Modicon M200 affected versions not specified Description A vulnerability exists due to a small space of random values, which could allow an attacker to brea...

8.3CVSS5.8AI score0.00296EPSS
SaveExploits0References11
CNVD
CNVD
added 2019/05/24 12:00 a.m.8 views

Schneider Electric SoMachine Basic and Schneider Electric Modicon M221 License Issue Vulnerability

Schneider Electric SoMachine Basic and Schneider Electric Modicon M221 are both products of Schneider Electric, France.Schneider Electric SoMachine Basic is a suite of software for programming logic controllers. The Schneider Electric Modicon M221 is a programmable logic controller. An...

5.5CVSS7AI score0.0031EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/05/24 12:00 a.m.10 views

Schneider Electric SoMachine Basic and Schneider Electric Modicon M221 Input Validation Error Vulnerability

Schneider Electric SoMachine Basic and Schneider Electric Modicon M221 are both products of Schneider Electric, France.Schneider Electric SoMachine Basic is a suite of software for programming logic controllers. The Schneider Electric Modicon M221 is a programmable logic controller. An input...

5.3CVSS6.9AI score0.01339EPSS
SaveExploits0References1
OSV
OSV
added 2019/05/22 8:29 p.m.6 views

CVE-2018-7823

A Environment CWE-2 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause remote launch of SoMachine Basic when sending crafted ethernet message...

5.3CVSS5.8AI score0.01339EPSS
SaveExploits0References1
NVD
NVD
added 2019/05/22 8:29 p.m.35 views

CVE-2018-7823

A Environment CWE-2 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause remote launch of SoMachine Basic when sending crafted ethernet message...

5.3CVSS5.2AI score0.01339EPSS
SaveExploits0References1
OSV
OSV
added 2019/05/22 8:29 p.m.7 views

CVE-2018-7821

An Environment CWE-2 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated...

7.5CVSS5.8AI score0.01096EPSS
SaveExploits0References1
NVD
NVD
added 2019/05/22 8:29 p.m.30 views

CVE-2018-7822

An Incorrect Default Permissions CWE-276 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic...

5.5CVSS5.4AI score0.0031EPSS
SaveExploits0References1
NVD
NVD
added 2019/05/22 8:29 p.m.23 views

CVE-2018-7821

An Environment CWE-2 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated...

7.5CVSS7.5AI score0.01096EPSS
SaveExploits0References1
OSV
OSV
added 2019/05/22 8:29 p.m.8 views

CVE-2018-7822

An Incorrect Default Permissions CWE-276 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic...

5.5CVSS5.8AI score0.0031EPSS
SaveExploits0References1
Prion
Prion
added 2019/05/22 8:29 p.m.30 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

6.4CVSS8.1AI score0.0125EPSS
SaveExploits0References1
Rows per page