1721 matches found
The vulnerability of the Custom Logo component of the Nagios XI monitoring tool, which allows a hacker to perform cross-site scripting attacks.
The vulnerability of the Custom Logo component of the Nagios XI monitoring tool is related to the lack of measures taken to protect the SQL query structure when processing the alt-text field. Exploiting this vulnerability allows a malicious actor to perform cross-site scripting attacks remotely...
Siemens LOGO! Insufficiently Protected Credentials (CVE-2017-12734)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25231)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program...
Siemens LOGO! Missing Authentication For Critical Function (CVE-2020-7589)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! CMR and SIMATIC RTU 3000 Improper Certificate Validation (CVE-2020-36478)
An issue was discovered in Mbed TLS before 2.25.0 and before 2.16.9 LTS and before 2.7.18 LTS. A NULL algorithm parameters entry looks identical to an array of REAL size zero and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate...
Siemens LOGO! Insufficient Verification of Data Authenticity (CVE-2022-36360)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker t...
Siemens LOGO! CMR and SIMATIC RTU 3000 Use of Insufficiently Random Values (CVE-2021-37186)
A vulnerability has been identified in LOGO! CMR2020 All versions V2.2, LOGO! CMR2040 All versions V2.2, SIMATIC RTU3010C All versions V4.0.9, SIMATIC RTU3030C All versions V4.0.9, SIMATIC RTU3031C All versions V4.0.9, SIMATIC RTU3041C All versions V4.0.9. The underlying TCP/IP stack does not...
Siemens LOGO! Web Server Buffer Copy Without Checking Size of Input (CVE-2020-7593)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants V1.81.01 - V1.81.03, LOGO! 8 BM incl. SIPLUS variants V1.82.01, LOGO! 8 BM incl. SIPLUS variants V1.82.02. A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacke...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25234)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions UDF in a password protected way. This...
Siemens LOGO! 8 BM Improper Handling of Exceptional Conditions (CVE-2020-25236)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The control logic CL the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the...
Siemens LOGO! 8 BM Plaintext Storage of a Password (CVE-2019-10921)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! 8 BM Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-25232)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25233)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Devices Improper Validation of Specified Index, Position, or Offset in Input (CVE-2022-36363)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory. This plugin only...
Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2019-10919)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...
Siemens LOGO! 8 BM Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-25230)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device. This plugin only works with Tenable.ot. Please visi...
Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2020-25228)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access...
Siemens LOGO! Channel Accessible By Non-Endpoint (CVE-2017-12735)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in- the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Devices Improper Input Validation (CVE-2022-36362)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be...
Siemens LOGO! 8 BM Insufficiently Protected Credentials (CVE-2020-25235)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins. This plugin on...