1721 matches found
CVE-2019-6571
The CVE-2019-6571 vulnerability affects Siemens LOGO!8 devices (firmware v1.80.x–v1.81.x for 6ED1052-xyyxx; and before v1.82.02 for 6ED1052-xyy08-0BA0). A network attacker can cause a Denial-of-Service by sending specially crafted packets to TCP port 10005 (no authentication, no user interaction)...
Siemens LOGO!8 License Issue Vulnerability
LOGO!8 is the 8th generation of Siemens intelligent logic controllers, the Nano PLC in the Siemens PLC family, which simplifies programming configurations, has an integrated panel for more displays, and can be easily networked and efficiently interconnected via the integrated Ethernet interface. ...
Siemens LOGO!8 Buffer Overflow Vulnerability
LOGO!8 is the 8th generation of Siemens intelligent logic controllers, the Nano PLC in the Siemens PLC family, which simplifies programming configurations, has an integrated panel for more displays, and can be easily networked and efficiently interconnected via the integrated Ethernet interface. ...
Siemens LOGO!8 Devices
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: LOGO!8 devices Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer, Session Fixation 2. RISK EVALUATION Successful exploitation of these...
Remote code execution
Bludit before 3.9.0 allows remote code execution for an authenticated user by uploading a php file while changing the logo through /admin/ajax/upload-logo...
CVE-2019-12548
Bludit before 3.9.0 allows remote code execution for an authenticated user by uploading a php file while changing the logo through /admin/ajax/upload-logo...
CVE-2019-12548
Bludit before 3.9.0 allows remote code execution for an authenticated user by uploading a php file while changing the logo through /admin/ajax/upload-logo...
CVE-2019-12548
Bludit before 3.9.0 allows remote code execution for an authenticated user by uploading a php file while changing the logo through /admin/ajax/upload-logo...
CVE-2019-12548
Bludit before 3.9.0 is vulnerable to remote code execution by an authenticated user who uploads a PHP file while changing the site logo via /admin/ajax/upload-logo. Root cause: an upload path/permission issue allows execution of injected PHP. A fix is available in Bludit 3.9.0 (as referenced by r...
Siemens LOGO! 8 Missing Authentication
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 Advisory ID: SYSS-2019-013 Product: LOGO! Manufacturer: Siemens Affected Versions: LOGO! 8 all versions Tested Versions: LOGO! 8, 6ED1052-2MD00-0BA8 FS:03, 0BA8.Standard V1.08.03 Vulnerability Type: Missing Authentication for Critical Function CWE-3...
Siemens LOGO! 8 Hard-Coded Cryptographic Key
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 Advisory ID: SYSS-2019-012 Product: LOGO! Manufacturer: Siemens Affected Versions: LOGO! 8 all versions Tested Versions: LOGO! 8, 6ED1052-2MD00-0BA8 FS:03, 0BA8.Standard V1.08.03 Vulnerability Type: Use of Hard-coded Cryptographic Key CWE-321 Risk...
Siemens LOGO! 8 Recoverable Password Format Vulnerability
Due to storing passwords in a recoverable format on Siemens LOGO! 8 PLCs, an attacker can gain access to configured passwords as cleartext. Siemens LOGO! 8 Recoverable Password Format Vulnerability Product: LOGO! Manufacturer: Siemens Affected Versions: LOGO! 8 all versions Tested Versions: LOGO!...
Siemens LOGO! 8 Recoverable Password Format
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 Advisory ID: SYSS-2019-014 Product: LOGO! Manufacturer: Siemens Affected Versions: LOGO! 8 all versions Tested Versions: LOGO! 8, 6ED1052-2MD00-0BA8 FS:03, 0BA8.Standard V1.08.03 Vulnerability Type: Storing Passwords in a Recoverable Format CWE-257...
Siemens LOGO! 8 Hard-Coded Cryptographic Key Vulnerability
Due to the use of a hard-coded cryptographic key, an attacker can put the integrity and confidentiality of encrypted data of all Siemens LOGO! 8 PLCs using this key at risk, for instance decrypting network communication during a man-in-the-middle attack. Siemens LOGO! 8 Hard-Coded Cryptographic K...
Siemens LOGO! 8 Missing Authentication Vulnerability
Due to storing passwords in a recoverable format on Siemens LOGO! 8 PLCs, an attacker can gain access to configured passwords as cleartext. Siemens LOGO! 8 Missing Authentication Vulnerability Product: LOGO! Manufacturer: Siemens Affected Versions: LOGO! 8 all versions Tested Versions: LOGO! 8,...
CVE-2019-10924
A vulnerability has been identified in LOGO! Soft Comfort All versions V8.3. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated...
CVE-2019-10920
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...
CVE-2019-10920
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...
CVE-2019-10921
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...
CVE-2019-10924
A vulnerability has been identified in LOGO! Soft Comfort All versions V8.3. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated...