Lucene search
+L

163 matches found

OSV
OSV
added 2019/05/14 8:29 p.m.10 views

CVE-2019-10919

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...

9.4CVSS7.2AI score0.02746EPSS
SaveExploits3References5
NVD
NVD
added 2019/05/14 8:29 p.m.31 views

CVE-2019-10919

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...

9.4CVSS9AI score0.02746EPSS
SaveExploits3References5
Prion
Prion
added 2019/05/14 8:29 p.m.18 views

Security feature bypass

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...

7.5CVSS8.8AI score0.02746EPSS
SaveExploits3References5Affected Software1
Prion
Prion
added 2019/05/14 8:29 p.m.20 views

Hardcoded credentials

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...

5CVSS7.4AI score0.01504EPSS
SaveExploits2References5Affected Software1
Cvelist
Cvelist
added 2019/05/14 7:54 p.m.28 views

CVE-2019-10921

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...

7.2AI score0.02447EPSS
SaveExploits3References5
CVE
CVE
added 2019/05/14 7:54 p.m.136 views

CVE-2019-10920

CVE-2019-10920 affects Siemens LOGO! 8 BM (and SIPLUS variants) with all versions before 8.3. The issue is a vulnerability in which project data on the device, accessible via port 10005/tcp, can be decrypted due to a hard-coded encryption key, allowing an unauthenticated remote attacker to access...

7.5CVSS7.1AI score0.01504EPSS
SaveExploits2References5Affected Software1
Cvelist
Cvelist
added 2019/05/14 7:54 p.m.39 views

CVE-2019-10919

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...

9AI score0.02746EPSS
SaveExploits3References5
Cvelist
Cvelist
added 2019/05/14 7:54 p.m.38 views

CVE-2019-10920

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...

7.2AI score0.01504EPSS
SaveExploits2References5
CVE
CVE
added 2019/05/14 7:54 p.m.127 views

CVE-2019-10919

Siemens LOGO! 8 BM (including SIPLUS variants) is affected by CVE-2019-10919 in all versions prior to V8.3. The issue allows an unauthenticated attacker with network access to port 10005/tcp to reconfigure the device and exfiltrate project files, affecting confidentiality, integrity, and availabi...

9.4CVSS8.9AI score0.02746EPSS
SaveExploits3References5Affected Software1
CVE
CVE
added 2019/05/14 7:54 p.m.139 views

CVE-2019-10921

CVE-2019-10921 affects Siemens LOGO! 8 BM (incl. SIPLUS) with all versions prior to 8.3. The issue is plaintext storage of passwords in the project, allowing an unauthenticated attacker with network access to port 10005/tcp to obtain device passwords, impacting confidentiality. Public exploit det...

7.5CVSS7.2AI score0.02447EPSS
SaveExploits3References5Affected Software1
ICS
ICS
added 2019/05/14 12:00 a.m.134 views

Siemens LOGO! 8 BM (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.4 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: LOGO! 8 BM Vulnerabilities: Missing Authentication for Critical Function, Improper Handling of Extra Values, Plaintext Storage of a Password 2. UPDATE INFORMATION This updated...

9.4CVSS8.2AI score0.02746EPSS
SaveExploits8References9
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.18 views

Siemens LOGO!8 BM Devices Man-in-the-Middle

Binary data 720104.prm...

7.4CVSS7.3AI score0.01126EPSS
SaveExploits0References2
Prion
Prion
added 2017/08/30 7:29 p.m.18 views

Design/Logic Flaw

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...

5CVSS7.2AI score0.01449EPSS
SaveExploits0References2Affected Software1
NVD
NVD
added 2017/08/30 7:29 p.m.29 views

CVE-2017-12735

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic...

7.4CVSS7.3AI score0.01126EPSS
SaveExploits0References2
OSV
OSV
added 2017/08/30 7:29 p.m.10 views

CVE-2017-12735

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic...

7.4CVSS5.7AI score0.01126EPSS
SaveExploits0References2
NVD
NVD
added 2017/08/30 7:29 p.m.25 views

CVE-2017-12734

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...

7.5CVSS7.3AI score0.01449EPSS
SaveExploits0References2
Prion
Prion
added 2017/08/30 7:29 p.m.19 views

Design/Logic Flaw

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic...

5.8CVSS7.3AI score0.01126EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2017/08/30 7:00 p.m.62 views

CVE-2017-12734

Siemens LOGO! 8 BM (incl. SIPLUS variants): all versions prior to V1.81.2 are affected by CVE-2017-12734 (Insufficiently Protected Credentials). An attacker with network access to the integrated web server on port 80/tcp can obtain the session ID of an active user session, requiring a logged-in u...

7.5CVSS7.2AI score0.01449EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2017/08/30 7:00 p.m.70 views

CVE-2017-12735

Siemens LOGO! 8 BM (incl. SIPLUS variants) is affected by CVE-2017-12735. All versions before v8.3 are vulnerable to a Man-in-the-Middle attack that could allow an attacker to decrypt and modify traffic between the LOGO! BM and other devices. The issue is mitigated by updating to firmware v8.3 (n...

7.4CVSS7.2AI score0.01126EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2017/08/30 7:00 p.m.29 views

CVE-2017-12734

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...

7.3AI score0.01449EPSS
SaveExploits0References2
Rows per page
Query Builder