209 matches found
Rockwell Studio 5000 Logix Designer Installed (Windows)
Binary data rockwellstudio5000logixdesignerwininstalled.nbin...
Rockwell Studio 5000 Logix Designer < V34 Code Hiding
The version of Rockwell Studio 5000 Logix Designer installed on the remote Windows host is prior to V34. It is, therefore, affected by a vulnerability. - An attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to ...
Siemens Teamcenter Visualization and JT2Go
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2024-3493
CVE-2024-3493 affects Rockwell Automation ControlLogix 5580, GuardLogix 5580, CompactLogix 5380, and 1756-EN4TR. The root cause is improper input validation triggering a major nonrecoverable fault (MNRF) when a specific malformed fragmented packet is processed; exploitation can render the device ...
Rockwell Automation ControlLogix 5580, Guard Logix 5580, CompactLogix 5380和1756-EN4TR 安全漏洞
Rockwell Automation ControlLogix is a controller from Rockwell Automation USA. A security vulnerability exists in Rockwell Automation ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR, which stems from an invalid header value resulting in the presence of a security...
The vulnerability of Rockwell Automation’s programmable logic controllers ControlLogix, related to the execution of operations outside the buffer boundaries in memory, allows a hacker to trigger a malfunction during maintenance.
The vulnerability of Rockwell Automation’s programmable logic controllers ControlLogix lies in the fact that the output data may escape from memory into the operating system. Exploiting this vulnerability could allow a malicious actor to cause malfunctions during operation...
CVE-2024-21916
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault MNRF. The device will restart itself to recover from the MNRF...
Rockwell Automation ControlLogix 缓冲区错误漏洞
Rockwell Automation ControlLogix and GuardLogix are both Rockwell Automation controllers. A denial of service vulnerability exists in Rockwell Automation ControlLogix and GuardLogix, which can be exploited by an attacker to cause a denial of service condition by sending a specially crafted reques...
CVE-2023-49166
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Magic Logix MSync.This issue affects MSync: from n/a through 1.0.0...
CVE-2023-49166
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Magic Logix MSync.This issue affects MSync: from n/a through 1.0.0...
Sql injection
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Magic Logix MSync.This issue affects MSync: from n/a through 1.0.0...
CVE-2023-49166
CVE-2023-49166 affects the WordPress MSync plugin by Magic Logix, versioned as <= 1.0.0. The rooted issue is an SQL Injection caused by improper neutralization of input in SQL commands, enabling a malicious actor with administrator privileges to influence queries. Public sources in the connect...
CVE-2023-49166 WordPress MSync Plugin <= 1.0.0 is vulnerable to SQL Injection
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Magic Logix MSync.This issue affects MSync: from n/a through 1.0.0...
The vulnerability of the microprogramming software for Rockwell Automation communication modules 1756-EN2T, 1756-EN2TK, 1756-EN2TXT, 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT, 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT, 1756-EN2F, 1756-EN2FK, 1756-EN3TR, 1756-EN3TRK, 1756-EN4TR, 1756-EN4TRK, and 1756-EN4TRXT controllers from the Allen-Bradley ControlLogix series allows a intruder to cause a service failure.
The vulnerability of the microprogrammed software in the communication modules of Rockwell Automation’s controllers models 1756-EN2T, 1756-EN2TK, 1756-EN2TXT, 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT, 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT, 1756-EN2F, 1756-EN2FK, 1756-EN3TR, 1756-EN3TRK, 1756-EN4TR,...
Rockwell Automation Logix controllers Improper Input Validation (CVE-2022-3752)
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user wou...
CVE-2022-3156
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution...
CVE-2022-3156
CVE-2022-3156 affects Rockwell Automation Studio 5000 Logix Emulate, specifically versions around v.20-33. The root cause is improper access control (CWE-284) that grants elevated permissions on certain product services, potentially enabling remote code execution. The advisory notes a CVSS v3 bas...
CVE-2022-3156 Rockwell Automation Studio 5000 Logix Emulate Vulnerable to a Remote Code Execution Vulnerability
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution...
CVE-2022-3156 Rockwell Automation Studio 5000 Logix Emulate Vulnerable to a Remote Code Execution Vulnerability
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution...
Rockwell Automation Studio 5000 Logix Designer Access Control Error Vulnerability
Rockwell Automation Studio 5000 Logix Designer is a Windows-based application from Rockwell Automation, Inc. It is used to build programs for PLCs. An access control error vulnerability exists in Rockwell Automation Studio 5000 Logix Designer version v.20-33, which arises from a user being grante...