6712 matches found
CVE-2024-34661
Improper handling of insufficient permissions in Samsung Assistant prior to version 9.1.00.7 allows remote attackers to access location data. User interaction is required for triggering this vulnerability...
CVE-2024-34661
Improper handling of insufficient permissions in Samsung Assistant prior to version 9.1.00.7 allows remote attackers to access location data. User interaction is required for triggering this vulnerability...
PT-2024-31733
Name of the Vulnerable Software and Affected Versions: SolarWinds Serv-U affected versions not specified Description: The issue is a directory traversal vulnerability where remote code execution is possible depending on the privileges given to the authenticated user. This problem requires the use...
PT-2024-26082 · Samsung · Samsung Assistant
Name of the Vulnerable Software and Affected Versions: Samsung Assistant versions prior to 9.1.00.7 Description: The issue is related to the improper handling of insufficient permissions in Samsung Assistant, allowing remote attackers to access location data. User interaction is required for...
CVE-2024-33057
Transient DOS while parsing the multi-link element Control field when common information length check is missing before updating the location...
CVE-2024-33057 Buffer Over-read in WLAN Host Communication
Transient DOS while parsing the multi-link element Control field when common information length check is missing before updating the location...
CVE-2024-33057
CVE-2024-33057 concerns Qualcomm WLAN components and describes a Transient Denial of Service caused by parsing the multi-link element Control field when a common information length check is missing before updating the location. The primary documentation lists a High impact (CVSSv3.1: 7.5) with a ...
CVE-2024-38304
Dell PowerEdge Platform, 14G Intel BIOS versions prior to 2.22.x, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure...
CVE-2024-38304
Dell PowerEdge Platform, 14G Intel BIOS versions prior to 2.22.x, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure...
CVE-2024-38304
Dell PowerEdge Platform, 14G Intel BIOS versions prior to 2.22.x, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure...
CVE-2024-38304
Dell PowerEdge Platform, 14G Intel BIOS versions prior to 2.22.x, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure...
CVE-2024-6449
HyperView Geoportal Toolkit (versions
Failed to collect disk files location data. Timeout exceeded.
Challenge A Backup from Storage Snapshot BfSS job in Veeam Backup & Replication VBR for a vSphere virtual machine VM fails with the error: Failed to collect disk files location data. Timeout exceeded. Cause This error is displayed when the disk file location collection task, Map Disk Region, with...
The vulnerability of the SLP UDP server slpd-lite in the OpenBMC operating system allows a attacker to compromise the confidentiality, integrity, and accessibility of data.
The vulnerability of the SLP UDP server slpd-lite in the OpenBMC operating system is related to the copying of buffers without checking the size of the input data. Exploiting this vulnerability allows a remote attacker to compromise privacy, integrity, and accessibility by sending a specially...
OESA-2024-2043 python-webob security update
WebOb provides wrappers around the WSGI request environment, and an object to help create WSGI responses. The objects map much of the specified behavior of HTTP, including header parsing and accessors for other standard parts of the environment. Security Fixes: WebOb provides objects for HTTP...
CVE-2024-39776
Avtec Outpost stores sensitive information in an insecure location without proper access controls in place...
CVE-2024-39776
Avtec Outpost stores sensitive information in an insecure location without proper access controls in place...
CVE-2024-39776
CVE-2024-39776 affects Avtec Outpost storage of sensitive data under web root. Technical details from connected sources show affected products: Outpost 0810 (versions prior to 5.0.0) and Outpost Uploader Utility (prior to 5.0.0). Root cause described as storing sensitive information in an insecur...
CVE-2024-39776 Avtec Outpost Storage of File with Sensitive Data Under Web Root
Avtec Outpost stores sensitive information in an insecure location without proper access controls in place...
PT-2024-28670 · Avtec · Avtec Outpost
Name of the Vulnerable Software and Affected Versions: Avtec Outpost affected versions not specified Description: The issue concerns the storage of sensitive information in an insecure location without proper access controls in place. Recommendations: At the moment, there is no information about ...