Lucene search
+L

514 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/12/19 12:00 a.m.•2 views

CVE-2025-52692: Missing Authentication for Critical Function

Successful exploitation of the vulnerability could allow an attacker with local network access to send a specially crafted URL to access certain administration functions without login credentials...

8.8CVSS7.7AI score0.06364EPSS
SaveExploits3References3
osv_cve
osv_cve
•added 2025/12/16 3:15 a.m.•20 views

CVE-2025-14748

A vulnerability was determined in Ningyuanda TC155 57.0.2.0. This affects an unknown function of the file /onvif/deviceservice of the component ONVIF Device Management Service. Executing manipulation of the argument FactoryDefault with the input Hard can lead to improper access controls. The atta...

5.4CVSS5.5AI score0.00641EPSS
SaveExploits1References4
Cvelist
Cvelist
•added 2025/12/16 3:02 a.m.•55 views

CVE-2025-14749 Ningyuanda TC155 ONVIF PTZ Control device_service access control

A vulnerability was identified in Ningyuanda TC155 57.0.2.0. This impacts an unknown function of the file /onvif/deviceservice of the component ONVIF PTZ Control Interface. The manipulation leads to improper access controls. The attack requires being on the local network. The exploit is publicly...

6.3CVSS0.00789EPSS
SaveExploits1References4
EUVD
EUVD
•added 2025/12/16 3:02 a.m.•22 views

EUVD-2025-203496

A vulnerability was identified in Ningyuanda TC155 57.0.2.0. This impacts an unknown function of the file /onvif/deviceservice of the component ONVIF PTZ Control Interface. The manipulation leads to improper access controls. The attack requires being on the local network. The exploit is publicly...

6.3CVSS5.7AI score0.00789EPSS
SaveExploits1References5
CVE
CVE
•added 2025/12/16 3:02 a.m.•38 views

CVE-2025-14749

CVE-2025-14749 affects Ningyuanda TC155, version 57.0.2.0, specifically the ONVIF PTZ Control Interface component via the file /onvif/device_service. Root cause: improper access controls leading to unauthorized access. Attack requires local network access; exploit is publicly available. Implicati...

8.8CVSS6.2AI score0.00789EPSS
SaveExploits1References4Affected Software1
EUVD
EUVD
•added 2025/12/10 11:27 a.m.•21 views

EUVD-2025-202412

Bypass vulnerability in the authentication method in the GTT Tax Information System application, related to the Active Directory LDAP login method. Authentication is performed through a local WebSocket, but the web application does not properly validate the authenticity or origin of the data...

9.3CVSS6.2AI score0.00569EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/12/09 12:00 a.m.•12 views

CVE-2025-12945: Improper Input Validation

An improper input validation vulnerability in the NETGEAR Nighthawk R7000P end of service routers lets an authenticated administrator with local network access to the device, to execute OS command injections and make unauthorized modifications to the router software and functionality impacting it...

7.2CVSS6.2AI score0.01141EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2025/12/05 12:00 a.m.•10 views

CVE-2025-64056

File upload vulnerability in Fanvil x210 V2 2.12.20 allows unauthenticated attackers on the local network to store arbitrary files on the filesystem...

6AI score0.00228EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/11/13 2:03 p.m.•20 views

CVE-2025-11566

CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint...

6.9CVSS7.1AI score0.00448EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/11/12 12:00 a.m.•21 views

Schneider Electric PowerChute Serial Shutdown 安全漏洞

Schneider Electric PowerChute Serial Shutdown is a UPS management, normal shutdown, and energy management software from Schneider Electric France. A security vulnerability exists in Schneider Electric PowerChute Serial Shutdown that stems from improperly restricted authentication attempts, which...

6.9CVSS6.7AI score0.00448EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/11/09 9:30 a.m.•16 views

EUVD-2025-38445

A vulnerability was identified in TOZED ZLT T10 T10PLUS3.04.15. The affected element is an unknown function of the file /reqproc/procpost of the component Reboot Handler. Such manipulation leads to denial of service. Access to the local network is required for this attack to succeed. The exploit ...

5.3CVSS5.6AI score0.006EPSS
SaveExploits1References5
osv_cve
osv_cve
•added 2025/11/09 8:15 a.m.•14 views

CVE-2025-12917

A vulnerability was identified in TOZED ZLT T10 T10PLUS3.04.15. The affected element is an unknown function of the file /reqproc/procpost of the component Reboot Handler. Such manipulation leads to denial of service. Access to the local network is required for this attack to succeed. The exploit ...

5.3CVSS5.4AI score0.006EPSS
SaveExploits1References5
NVD
NVD
•added 2025/11/09 8:15 a.m.•28 views

CVE-2025-12917

A vulnerability was identified in TOZED ZLT T10 T10PLUS3.04.15. The affected element is an unknown function of the file /reqproc/procpost of the component Reboot Handler. Such manipulation leads to denial of service. Access to the local network is required for this attack to succeed. The exploit ...

5.3CVSS0.006EPSS
SaveExploits1References5
EUVD
EUVD
•added 2025/10/29 6:30 p.m.•20 views

EUVD-2025-36691

Incorrect access control on Dataphone A920 v2025.07.161103 exposes a service on port 8888 by default on the local network without authentication. This allows an attacker to interact with the device via a TCP socket without credentials. Additionally, sending an HTTP request to the service on port...

6.1AI score0.00344EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2025/10/27 12:00 a.m.•23 views

PT-2025-43891

Name of the Vulnerable Software and Affected Versions Tenda CH22 version 1.0.0.1 Description A flaw exists in the fromSetIpBind function within the /goform/SetIpBind file. Manipulating the page argument can lead to a buffer overflow. Exploitation of this issue requires local network access. The...

8.6CVSS6.9AI score0.05232EPSS
SaveExploits1References7
RedhatCVE
RedhatCVE
•added 2025/10/13 6:22 p.m.•26 views

CVE-2025-11640

A vulnerability was found in Tomofun Furbo 360 and Furbo Mini. This affects an unknown function of the component Bluetooth Low Energy. The manipulation results in cleartext transmission of sensitive information. Access to the local network is required for this attack. Attacks of this nature are...

5.3CVSS6.1AI score0.00217EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/10/12 6:30 p.m.•25 views

EUVD-2025-33904

A vulnerability was found in Tomofun Furbo 360 and Furbo Mini. This affects an unknown function of the component Bluetooth Low Energy. The manipulation results in cleartext transmission of sensitive information. Access to the local network is required for this attack. Attacks of this nature are...

3.1CVSS3.7AI score0.00217EPSS
SaveExploits0References4
osv_cve
osv_cve
•added 2025/10/12 6:15 p.m.•22 views

CVE-2025-11640

A vulnerability was found in Tomofun Furbo 360 and Furbo Mini. This affects an unknown function of the component Bluetooth Low Energy. The manipulation results in cleartext transmission of sensitive information. Access to the local network is required for this attack. Attacks of this nature are...

5.3CVSS5.4AI score0.00217EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2025/10/12 6:02 p.m.•34 views

CVE-2025-11640 Tomofun Furbo 360/Furbo Mini Bluetooth Low Energy cleartext transmission

A vulnerability was found in Tomofun Furbo 360 and Furbo Mini. This affects an unknown function of the component Bluetooth Low Energy. The manipulation results in cleartext transmission of sensitive information. Access to the local network is required for this attack. Attacks of this nature are...

3.1CVSS0.00217EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2025/10/12 12:00 a.m.•16 views

PT-2025-41726

Name of the Vulnerable Software and Affected Versions Tomofun Furbo 360 versions prior to FB0035 FW 036 Tomofun Furbo Mini versions prior to MC0020 FW 074 Description A flaw exists in the Bluetooth Handler component of Tomofun Furbo 360 and Furbo Mini. Exploitation of this issue can lead to a...

5.3CVSS4.5AI score0.0034EPSS
SaveExploits0References8
Rows per page
Query Builder