17184 matches found
CVE-2025-27689
Dell iDRAC Tools, versions prior to 11.3.0.0, contains an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges...
CVE-2025-4417
A cross-site scripting vulnerability exists in AVEVA PI Connector for CygNet Versions 1.6.14 and prior that, if exploited, could allow an administrator miscreant with local access to the connector admin portal to persist arbitrary JavaScript code that will be executed by other users who visit...
CVE-2025-4417 AVEVA PI Connector for CygNet Cross-site Scripting
A cross-site scripting vulnerability exists in AVEVA PI Connector for CygNet Versions 1.6.14 and prior that, if exploited, could allow an administrator miscreant with local access to the connector admin portal to persist arbitrary JavaScript code that will be executed by other users who visit...
CVE-2025-4417
CVE-2025-4417 – AVEVA PI Connector for CygNet Affected product: AVEVA PI Connector for CygNet, version 1.6.14 and prior. Vulnerability: Cross-site scripting (XSS) that, if exploited, could let an administrator with local access to the connector admin portal persist arbitrary JavaScript code to be...
CVE-2025-36573
Dell Smart Dock Firmware, versions prior to 01.00.08.01, contain an Insertion of Sensitive Information into Log File vulnerability. A user with local access could potentially exploit this vulnerability, leading to Information disclosure...
PT-2025-25331 · Dell · Dell Smart Dock Firmware
Name of the Vulnerable Software and Affected Versions: Dell Smart Dock Firmware versions prior to 01.00.08.01 Description: The issue concerns an Insertion of Sensitive Information into Log File, which could be exploited by a user with local access, potentially leading to information disclosure...
CVE-2025-33075
Improper link resolution before file access 'link following' in Windows Installer allows an authorized attacker to elevate privileges locally...
CVE-2025-33075
Improper link resolution before file access 'link following' in Windows Installer allows an authorized attacker to elevate privileges locally...
CVE-2025-33060
Out-of-bounds read in Windows Storage Management Provider allows an authorized attacker to disclose information locally...
CVE-2025-33059
Out-of-bounds read in Windows Storage Management Provider allows an authorized attacker to disclose information locally...
CVE-2025-32721
Improper link resolution before file access 'link following' in Windows Recovery Driver allows an authorized attacker to elevate privileges locally...
CVE-2025-32716
Out-of-bounds read in Windows Media allows an authorized attacker to elevate privileges locally...
USN-7560-1 amd64-microcode vulnerability
Josh Eads, Kristoffer Janke, Eduardo Nava, Tavis Ormandy and Matteo Rizzo discovered that AMD Microcode incorrectly verified signatures. An attacker with local administrator privilege could possibly use this issue to cause loss of confidentiality and integrity of a confidential guest running unde...
CVE-2025-5640
A vulnerability was found in PX4-Autopilot 1.12.3. It has been classified as problematic. This affects the function MavlinkReceiver::handlemessagetrajectoryrepresentationwaypoints of the file mavlinkreceiver.cpp of the component TRAJECTORYREPRESENTATIONWAYPOINTS Message Handler. The manipulation...
CVE-2025-5474
2BrightSparks SyncBackFree Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of 2BrightSparks SyncBackFree. An attacker must first obtain the ability to execute low-privileged code on the target syst...
CVE-2024-13087
A command injection vulnerability has been reported to affect QHora. If an attacker gains local network access who have also gained an administrator account, they can then exploit the vulnerability to execute arbitrary commands. We have already fixed the vulnerability in the following version:...
CVE-2025-3321
A predefined administrative account is not documented and cannot be deactivated. This account cannot be misused from the network, only by local users on the server...
SUSE CVE-2025-5644
A vulnerability, which was classified as problematic, has been found in Radare2 5.9.9. Affected by this issue is the function rconsflush in the library /libr/cons/cons.c of the component radiff2. The manipulation of the argument -T leads to use after free. Local access is required to approach thi...
PT-2025-24052 · B. Braun · B. Braun Onlinesuite
Name of the Vulnerable Software and Affected Versions: B.Braun OnlineSuite versions prior to AP 3.0 Description: A predefined administrative account is not documented and cannot be deactivated. This account cannot be misused from the network, only by local users on the server. The issue affects t...
UBUNTU-CVE-2025-5644
A vulnerability, which was classified as problematic, has been found in Radare2 5.9.9. Affected by this issue is the function rconsflush in the library /libr/cons/cons.c of the component radiff2. The manipulation of the argument -T leads to use after free. Local access is required to approach thi...