Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25229)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...
Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2019-10919)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...
Siemens LOGO! 8 BM Devices Improper Validation of Specified Index, Position, or Offset in Input (CVE-2022-36363)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory. This plugin only...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25233)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! Insufficient Verification of Data Authenticity (CVE-2022-36360)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker t...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25234)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions UDF in a password protected way. This...
Siemens LOGO! Web Server Buffer Copy Without Checking Size of Input (CVE-2020-7593)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants V1.81.01 - V1.81.03, LOGO! 8 BM incl. SIPLUS variants V1.82.01, LOGO! 8 BM incl. SIPLUS variants V1.82.02. A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacke...
Siemens LOGO! Insufficiently Protected Credentials (CVE-2017-12734)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...
Siemens LOGO! 8 BM Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-25232)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port...
Siemens LOGO! 8 BM Plaintext Storage of a Password (CVE-2019-10921)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! 8 BM Insufficiently Protected Credentials (CVE-2020-25235)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins. This plugin on...
Siemens LOGO! Channel Accessible By Non-Endpoint (CVE-2017-12735)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in- the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Improper Handling of Extra Values (CVE-2019-10920)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...
Siemens LOGO! CMR and SIMATIC RTU 3000 Use of Insufficiently Random Values (CVE-2021-37186)
A vulnerability has been identified in LOGO! CMR2020 All versions V2.2, LOGO! CMR2040 All versions V2.2, SIMATIC RTU3010C All versions V4.0.9, SIMATIC RTU3030C All versions V4.0.9, SIMATIC RTU3031C All versions V4.0.9, SIMATIC RTU3041C All versions V4.0.9. The underlying TCP/IP stack does not...
Siemens LOGO! Missing Authentication For Critical Function (CVE-2020-7589)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...
CVE-2023-40932
A Cross-site scripting XSS vulnerability in Nagios XI version 5.11.1 and below allows authenticated attackers with access to the custom logo component to inject arbitrary javascript or HTML via the alt-text field. This affects all pages containing the navbar including the login page which means t...
CVE-2023-40932
A Cross-site scripting XSS vulnerability in Nagios XI version 5.11.1 and below allows authenticated attackers with access to the custom logo component to inject arbitrary javascript or HTML via the alt-text field. This affects all pages containing the navbar including the login page which means t...
Cross site scripting
A Cross-site scripting XSS vulnerability in Nagios XI version 5.11.1 and below allows authenticated attackers with access to the custom logo component to inject arbitrary javascript or HTML via the alt-text field. This affects all pages containing the navbar including the login page which means t...
Nagios XI Cross-Site Scripting Vulnerability
Nagios XI is a suite of IT infrastructure monitoring solutions from the US-based Nagios. The solution supports monitoring and alerting of applications, services, operating systems, and more. A cross-site scripting vulnerability exists in Nagios XI 5.11.1 and earlier versions, which originates fro...
Stored XSS at LOGO+USER menu
Description Please enter a description of the vulnerability. Proof of Concept login with admin account visit https://demo.instantcms.io/admin/widgets?templatename=modern&scrollto=row-14 navigate to logo+user menu tab insert payload 1" onmouseover = "alert'hackedbytisha' at Parent row Tag CSS clas...