610 matches found
CVE-2018-17482
CVE-2018-17482 affects Lobby Track Desktop (visitor management app by Jolly Technologies). A vulnerability in the kiosk-mode Reports component allows a local attacker to disclose sensitive information by visiting the kiosk and interacting with Reports, potentially gaining access to all visitor re...
CVE-2018-17482
Lobby Track Desktop could allow a local attacker to obtain sensitive information, caused by an error in Reports while in kiosk mode. By visiting the kiosk and clicking on reports, an attacker could exploit this vulnerability to gain access to all visitor records and obtain sensitive information...
The vulnerability of the fly-admin-local package on the Astra Linux operating system allows a hacker to influence certain security policy rules.
The vulnerability of the fly-admin-local package in the Astra Linux operating system is related to an error in enabling the “kiosk” mode when the /etc/xdg/rusbitech file and the astra-console group are absent. Exploiting this vulnerability can allow a perpetrator to influence certain security...
CVE-2018-19012
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...
CVE-2018-19012
The CVE-2018-19012 issue affects Dräger Infinity Delta, Delta XL, Kappa, and Infinity Explorer C700 (all versions). The root cause is improper privilege management in a dialog that allows breaking out of kiosk mode, enabling an attacker to reach the underlying OS and take control of the system. T...
QIWI: Каким-то образом получил чужой платеж к себе на копилку https://qiwi.me/undefined
Зарегистрировал копилку https://qiwi.me/undefined Выбрал такое имя не случайно, иногда с ним происходят забавные баги. Через некоторое время стали приходить случайные платежи от неизвестных пользователей...
CVE-2018-8853
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in...
CVE-2018-8861
Vulnerabilities within the Philips Brilliance CT kiosk environment Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior could enable a limited-access kiosk user or an unauthorized...
CVE-2018-8853
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in...
CVE-2018-8861
Vulnerabilities within the Philips Brilliance CT kiosk environment Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior could enable a limited-access kiosk user or an unauthorized...
CVE-2018-8861
Vulnerabilities within the Philips Brilliance CT kiosk environment Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior could enable a limited-access kiosk user or an unauthorized...
CVE-2018-8861
Vulnerabilities within the Philips Brilliance CT kiosk environment Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior could enable a limited-access kiosk user or an unauthorized...
CVE-2018-8861
Philips Brilliance CT kiosk devices (Brilliance 64 v2.6.2 and earlier; Brilliance iCT v4.1.6 and earlier; Brilliance iCT SP v3.2.4 and earlier; Brilliance CT Big Bore v2.3.5 and earlier) have vulnerabilities that could allow a limited‑access kiosk user or an attacker to break out of the kiosk con...
Philips Brilliance CT Scanners Unauthorized Access Vulnerability
The Philips Brilliance 64, among others, is a CT scanner device from the Dutch company Philips. A security vulnerability exists in the kiosk environment in several Philips Brilliance CT devices. An attacker can use this vulnerability to escape the limitations of the kiosk environment and gain...
How to restrict users to access device settings on Samsung devices in KIOSK mode
Restrict users to access device settings in Samsung KIOSK mode...
How to configure, deploy, and troubleshoot StoreFront-based assigned application actions in Workspace Environment Management (WEM)
Feature Overview From WEM version 4.6, assigned Applications actions can be applications published from a XenApp & XenDesktop Site. This feature addresses a common customer request to have WEM include the ability to provide published application shortcuts in desktop sessions and through the WEM...
CVE-2018-5438
Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record EMR system, where ISCV is in KIOSK mo...
CVE-2018-5438
Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record EMR system, where ISCV is in KIOSK mo...
Session fixation
Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record EMR system, where ISCV is in KIOSK mo...
CVE-2018-5438
The CVE-2018-5438 vulnerability affects Philips IntelliSpace Cardiovascular System (ISCV) prior to version 2.3.0. The issue is an insufficient session expiration that can allow reuse of a previously authenticated session when ISCV is used with an EMR in kiosk mode across multiple users using Wind...