CVE-2019-25717

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00165EPSS
Exploits0References2
CVE
CVE
added 2026/06/02 1:42 p.m.14 views

CVE-2019-25717

CVE-2019-25717 affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. The vulnerability allows unauthenticated attackers over a network to access exposed log files, exposing device internals, location data, and wired network configuration details. No root cause or remediation detail...

5.3CVSS5.8AI score0.00165EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/06/02 1:42 p.m.35 views

CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00165EPSS
Exploits0References2
CNNVD
CNNVD
added 2026/06/02 12:0 a.m.3 views

Dräger多款产品 安全漏洞

Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...

5.3CVSS5.5AI score0.00165EPSS
Exploits0References2
NVD
NVD
added 2026/06/01 10:16 p.m.11 views

CVE-2019-25716

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00204EPSS
Exploits0References2
CVE
CVE
added 2026/06/01 9:15 p.m.14 views

CVE-2019-25716

The CVE affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. A denial-of-service flaw lets an attacker send malformed network packets to reboot the device, disrupting monitoring until it reverts to default configuration and loses network connectivity. Documented metrics show CVSSv...

7.1CVSS5.8AI score0.00204EPSS
Exploits0References2