Lucene search
+L

564 matches found

OSV
OSV
•added 2019/08/17 6:15 p.m.•25 views

UBUNTU-CVE-2019-15132

Zabbix through 4.4.0alpha1 allows User Enumeration. With login requests, it is possible to enumerate application usernames based on the variability of server responses e.g., the "Login name or password is incorrect" and "No permissions for system access" messages, or just blocking for a number of...

5.3CVSS6.8AI score0.02027EPSS
SaveExploits0References4
Hacker One
Hacker One
•added 2019/08/05 3:10 p.m.•72 views

MyEtherWallet: Local Storage Custom Node Credentials Leak

Summary Credentials for a custom node are stored in plain text inside Local Storage on the user's machine. If this node is configured in a certain way this could lead to the theft of any funds in accounts attached to this node, by a local attacker. And if not configured this way, an attacker coul...

7AI score
SaveExploits0
NVD
NVD
•added 2019/05/29 9:29 p.m.•30 views

CVE-2019-11895

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...

7.1CVSS5.2AI score0.00981EPSS
SaveExploits0References1
Prion
Prion
•added 2019/05/29 9:29 p.m.•24 views

Improper access control

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...

7.1CVSS5.3AI score0.00981EPSS
SaveExploits0References1Affected Software1
Prion
Prion
•added 2019/05/29 8:29 p.m.•25 views

Improper access control

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...

6.8CVSS7.8AI score0.01029EPSS
SaveExploits0References1Affected Software1
NVD
NVD
•added 2019/05/29 8:29 p.m.•33 views

CVE-2019-11892

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...

8CVSS7.6AI score0.01029EPSS
SaveExploits0References1
CVE
CVE
•added 2019/05/29 8:07 p.m.•168 views

CVE-2019-11895

The CVE-2019-11895 entry concerns an improper access control vulnerability in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) prior to 9.8.905, which can lead to denial of service affecting the SHC and connected sensors/actuators. Exposure requires the attacker to have already pai...

7.1CVSS5.2AI score0.00981EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/05/29 8:07 p.m.•42 views

CVE-2019-11895 Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...

5.3CVSS5.3AI score0.00981EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/05/29 7:55 p.m.•36 views

CVE-2019-11892 Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...

7.5CVSS7.8AI score0.01029EPSS
SaveExploits0References1
CVE
CVE
•added 2019/05/29 7:55 p.m.•168 views

CVE-2019-11892

The CVE-2019-11892 issue affects the Bosch Smart Home Controller (SHC) JSON-RPC interface. Affected component: SHC’s JSON-RPC layer. Root cause: improper access control could allow reading or modification of SHC configuration and could trigger and restore backups. Exploitation requirements: an at...

8CVSS7.7AI score0.01029EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2019/05/29 12:00 a.m.•4 views

PT-2019-12549

Name of the Vulnerable Software and Affected Versions Bosch Smart Home Controller versions prior to 9.8.905 Description A potential improper access control issue exists in the JSON-RPC interface that may allow reading or modification of the configuration or triggering and restoring backups. To...

8CVSS0.01029EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2019/05/29 12:00 a.m.•3 views

PT-2019-12552

Name of the Vulnerable Software and Affected Versions Bosch Smart Home Controller versions prior to 9.8.905 Description A potential improper access control issue exists in the JSON-RPC interface that may result in a denial of service of the controller and connected devices. To exploit this, an...

7.1CVSS0.00981EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/29 12:00 a.m.•6 views

CVE-2019-11895: Improper Access Control

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...

7.1CVSS5.8AI score0.00981EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/29 12:00 a.m.•9 views

CVE-2019-11892: Improper Access Control

A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...

8CVSS5.8AI score0.01029EPSS
SaveExploits0References2
OSV
OSV
•added 2019/04/11 9:29 p.m.•19 views

CVE-2018-20487

An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...

8.8CVSS5.8AI score0.01871EPSS
SaveExploits1References2
Prion
Prion
•added 2019/04/11 9:29 p.m.•29 views

Design/Logic Flaw

An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...

9CVSS8.4AI score0.01871EPSS
SaveExploits1References2Affected Software1
NVD
NVD
•added 2019/04/11 9:29 p.m.•32 views

CVE-2018-20487

An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...

9CVSS8.5AI score0.01871EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2019/04/11 8:21 p.m.•45 views

CVE-2018-20487

An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...

8.5AI score0.01871EPSS
SaveExploits1References2
CVE
CVE
•added 2019/04/11 8:21 p.m.•70 views

CVE-2018-20487

This CVE affects the firewall3 component of Inteno IOPSYS 1.0–3.16. A JSON-RPC call to add a firewall rule as an “include” can point the path to a malicious script/binary, which is executed as root when changes are committed. Affected software: Inteno IOPSYS firewall3. Root-level impact: arbitrar...

9CVSS8.4AI score0.01871EPSS
SaveExploits1References2Affected Software1
Positive Technologies
Positive Technologies
•added 2019/04/11 12:00 a.m.•5 views

PT-2019-10078

Name of the Vulnerable Software and Affected Versions: Inteno IOPSYS versions 1.0 through 3.16 Description: An issue was discovered in the firewall3 component. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the path argument to a malicious script or...

9CVSS0.01871EPSS
SaveExploits1References4
Rows per page
Query Builder