564 matches found
UBUNTU-CVE-2019-15132
Zabbix through 4.4.0alpha1 allows User Enumeration. With login requests, it is possible to enumerate application usernames based on the variability of server responses e.g., the "Login name or password is incorrect" and "No permissions for system access" messages, or just blocking for a number of...
MyEtherWallet: Local Storage Custom Node Credentials Leak
Summary Credentials for a custom node are stored in plain text inside Local Storage on the user's machine. If this node is configured in a certain way this could lead to the theft of any funds in accounts attached to this node, by a local attacker. And if not configured this way, an attacker coul...
CVE-2019-11895
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...
Improper access control
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...
Improper access control
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...
CVE-2019-11892
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...
CVE-2019-11895
The CVE-2019-11895 entry concerns an improper access control vulnerability in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) prior to 9.8.905, which can lead to denial of service affecting the SHC and connected sensors/actuators. Exposure requires the attacker to have already pai...
CVE-2019-11895 Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...
CVE-2019-11892 Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...
CVE-2019-11892
The CVE-2019-11892 issue affects the Bosch Smart Home Controller (SHC) JSON-RPC interface. Affected component: SHC’s JSON-RPC layer. Root cause: improper access control could allow reading or modification of SHC configuration and could trigger and restore backups. Exploitation requirements: an at...
PT-2019-12549
Name of the Vulnerable Software and Affected Versions Bosch Smart Home Controller versions prior to 9.8.905 Description A potential improper access control issue exists in the JSON-RPC interface that may allow reading or modification of the configuration or triggering and restoring backups. To...
PT-2019-12552
Name of the Vulnerable Software and Affected Versions Bosch Smart Home Controller versions prior to 9.8.905 Description A potential improper access control issue exists in the JSON-RPC interface that may result in a denial of service of the controller and connected devices. To exploit this, an...
CVE-2019-11895: Improper Access Control
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to...
CVE-2019-11892: Improper Access Control
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller SHC before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary...
CVE-2018-20487
An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...
Design/Logic Flaw
An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...
CVE-2018-20487
An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...
CVE-2018-20487
An issue was discovered in the firewall3 component in Inteno IOPSYS 1.0 through 3.16. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the "path" argument to a malicious script or binary. This gets executed as root when the firewall changes are...
CVE-2018-20487
This CVE affects the firewall3 component of Inteno IOPSYS 1.0–3.16. A JSON-RPC call to add a firewall rule as an “include” can point the path to a malicious script/binary, which is executed as root when changes are committed. Affected software: Inteno IOPSYS firewall3. Root-level impact: arbitrar...
PT-2019-10078
Name of the Vulnerable Software and Affected Versions: Inteno IOPSYS versions 1.0 through 3.16 Description: An issue was discovered in the firewall3 component. The attacker must make a JSON-RPC method call to add a firewall rule as an "include" and point the path argument to a malicious script or...