Lucene search
K

6 matches found

CNNVD
CNNVD
added 2022/02/11 12:0 a.m.1 views

Schneider Electric Interactive Graphical SCADA System访问控制错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An access control error vulnerability exists in the Schneider Electric Interactive Graphical...

9.1CVSS5.9AI score0.0032EPSS
Exploits0References3
OSV
OSV
added 2022/02/09 11:15 p.m.0 views

CVE-2022-24315

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS5.8AI score
Exploits0References2
CNNVD
CNNVD
added 2021/10/12 12:0 a.m.1 views

Schneider Electric IGSS 路径遍历漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is an advanced SCADA system for monitoring and controlling industrial processes.Schneider Electric Interactive Graphical SCADA System is vulnerable to a path traversal vulnerability, which can be exploited by attackers to read arbitrary...

7.5CVSS5.7AI score0.0049EPSS
Exploits0References6
CNNVD
CNNVD
added 2020/11/17 12:0 a.m.1 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that...

7.8CVSS7.8AI score0.0066EPSS
Exploits0References5
CNNVD
CNNVD
added 2020/11/17 12:0 a.m.3 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...

7.8CVSS7.8AI score0.0066EPSS
Exploits0References5
ATTACKERKB
ATTACKERKB
added 2011/07/29 7:55 p.m.1 views

CVE-2011-2959

Stack-based buffer overflow in the Open Database Connectivity ODBC service Odbcixv9se.exe in 7-Technologies Interactive Graphical SCADA System IGSS 9 and earlier allows remote attackers to cause a denial of service crash and possibly execute arbitrary code via a crafted packet to TCP port 22202...

10CVSS6.4AI score0.12293EPSS
Exploits0References5
Rows per page
Query Builder