Lucene search
K

70 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-19769

Malware in sbrugna...

6.8CVSS6.6AI score0.00053EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-19771

Malware in sbrugna...

6.5CVSS6.5AI score0.00141EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2011-3349

Malware in sbrugna...

4CVSS6.4AI score0.01107EPSS
Exploits0References10
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-19789

Malware in sbrugna...

5.7CVSS5.8AI score0.00078EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-19785

Malware in sbrugna...

5.7CVSS5.8AI score0.00094EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-19779

Malware in sbrugna...

6.5CVSS6.5AI score0.00068EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-19782

Malware in sbrugna...

5.7CVSS5.8AI score0.00089EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2020-19777

Malware in sbrugna...

8.8CVSS8.6AI score0.00097EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-3075

Malware in sbrugna...

8.1CVSS8AI score0.00085EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-19781

Malware in sbrugna...

6.5CVSS6.5AI score0.00072EPSS
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/05/22 5:33 p.m.5 views

CVE-2020-27268

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a client-side control vulnerability in the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows physically proximate attackers to bypass checks for default PINs via Bluetooth Low Energy...

6.5CVSS6.9AI score0.00072EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 4:35 p.m.6 views

CVE-2020-27270

SOOIL Developments CoLtd DiabecareRS, AnyDana-i ,AnyDana-A, communication protocol of the insulin pump & AnyDana-i,AnyDana-A mobile apps doesnt use adequate measures to protect encryption keys in transit which allows unauthenticated physically proximate attacker to sniff keys via BLE...

5.7CVSS6.9AI score0.00048EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 4:15 p.m.5 views

CVE-2020-27256

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a hard-coded physician PIN in the physician menu of the insulin pump allows attackers with physical access to change insulin therapy settings...

6.8CVSS6.6AI score0.00053EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 3:25 p.m.8 views

CVE-2020-27269

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications lacks replay protection measures, which allows unauthenticated, physically proximate attackers to replay communication sequences...

5.7CVSS6.9AI score0.00089EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 3:24 p.m.7 views

CVE-2020-27264

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications use deterministic keys, which allows unauthenticated, physically proximate attackers to brute-force the keys via Bluetooth Low...

8.8CVSS6.9AI score0.00097EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 3:24 p.m.7 views

CVE-2020-27266

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a client-side control vulnerability in the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows physically proximate attackers to bypass user authentication checks via Bluetooth Low Energy...

6.5CVSS7.1AI score0.00068EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 3:24 p.m.7 views

CVE-2020-27258

In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, an information disclosure vulnerability in the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows unauthenticated attackers to extract the pump’s keypad lock PIN via Bluetooth...

6.5CVSS6.6AI score0.00141EPSS
Exploits0
RedhatCVE
RedhatCVE
added 2025/02/05 3:12 p.m.7 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS6.9AI score0.00085EPSS
Exploits0References1
Malwarebytes
Malwarebytes
added 2022/09/22 1:15 p.m.16 views

Medtronic's MiniMed 600 series insulin pumps potentially at risk of compromise, says FDA

The US FDA Food and Drug Administration has warned users of Medtronic's MiniMed 600 Series Insulin Pump System--specifically, models for MiniMed 630G and MiniMed 670G--that their medical devices have a cybersecurity issue with its communication protocol. If compromised, attackers could gain...

2.2AI score
Exploits0
Prion
Prion
added 2021/12/01 4:15 p.m.14 views

Authentication flaw

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

4.8CVSS8AI score0.00085EPSS
Exploits0References2
Rows per page