Authentication Bypass Vulnerability in Multiple Hospira Products
The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. An authentication bypass vulnerability exists in multiple Hospira products. An attacker could use this vulnerability to bypass the authentication mechanism a...
Hardcoded Password Security Bypass Vulnerability in Multiple Hospira Products
The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A security bypass vulnerability exists in multiple Hospira products. An attacker could exploit this vulnerability to bypass security restrictions and gain...
Local Security Bypass Vulnerability in Multiple Hospira Products
The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A local security bypass vulnerability exists in multiple Hospira products. A local attacker could exploit this vulnerability to bypass security restrictions...
Stack Buffer Overflow Vulnerability in Multiple Hospira Products
The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A stack buffer overflow vulnerability exists in multiple Hospira products due to the program failing to perform proper boundary checks on user-submitted inpu...
Hospira LifeCare PCA Infusion System Security Restriction Bypass Vulnerability
The Hospira LifeCare PCA Infusion System is an IV infusion pump that delivers medications to patients. Hospira LifeCare PCA Infusion System 5.0 and earlier versions are vulnerable to a data authenticity validation vulnerability in their implementation by uploading software updates, configuration...
CVE-2015-3459
The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...
CVE-2015-3459
Hospira LifeCare PCA Infusion System (pre-7.0) has an unauthenticated root Telnet access in the device’s communication module, allowing remote modification of pump configuration. Connected sources confirm affected products include LifeCare PCA Infusion System versions 5.0 and older, with exploita...
PT-2015-1287
Name of the Vulnerable Software and Affected Versions Hospira LifeCare PCA Infusion System versions prior to 7.0 Description The issue concerns the lack of authentication for Telnet sessions on the communication module of the affected device. This allows a remote attacker to gain control over the...
CVE-2015-3459: Undefined Security Weakness
The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...
Baxter SIGMA Spectrum Infusion System Vulnerabilities
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on June 30, 2015, and is being released to the NCCIC/ICS-CERT web site. Researcher Jared Bird with Allina IS Security identified four vulnerabilities in Baxter’s SIGMA Spectrum Infusion System. Baxter has released a...
Hospira Symbiq Infusion System Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on June 23, 2015, and is being released to the NCCIC/ICS-CERT web site. Independent researcher Billy Rios identified a vulnerability in Hospira’s Symbiq Infusion System, which can be exploited to remotely control th...
Hospira Plum A+ and Symbiq Infusion Systems Vulnerabilities
OVERVIEW Independent researcher Billy Rios has identified vulnerabilities in Hospira’s Plum A+ Infusion System that are similar to vulnerabilities identified in Hospira’s LifeCare PCA Infusion System discussed in advisory, ICSA-15-125-01B Hospira LifeCare PCA Infusion System Vulnerabilities...