Baxter Spectrum WBM Trust Management Issues Vulnerability (CNVD-2021-21077)

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum is vulnerable to a trust management issue that could be exploited by an attacke...

9.8CVSS6.7AI score0.01676EPSS
SaveExploits0References1
ThreatPost
ThreatPost
•added 2019/06/13 6:41 p.m.•175 views

Max-Severity Bug in Infusion Pump Gateway Puts Lives at Risk

Researchers have disclosed two separate vulnerabilities within the Becton Dickinson Alaris Gateway Workstation for medical infusion pumps in hospitals, one carrying a critical rating of 10 out of 10 on the CVSS v.3 severity scale. Alaris Gateway Workstations power, monitor and control infusion...

7.5CVSS0.02528EPSS
SaveExploits0References8
OSV
OSV
•added 2018/02/15 10:29 a.m.•13 views

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

8.1CVSS5.8AI score0.01851EPSS
SaveExploits0References2
OSV
OSV
•added 2018/02/15 10:29 a.m.•17 views

CVE-2017-12726

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...

7.3CVSS5.8AI score0.01082EPSS
SaveExploits0References2
OSV
OSV
•added 2018/02/15 10:29 a.m.•16 views

CVE-2017-12722

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the...

5.3CVSS5.8AI score0.02415EPSS
SaveExploits0References3
OSV
OSV
•added 2018/02/15 10:29 a.m.•23 views

CVE-2017-12725

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...

5.6CVSS5.8AI score0.00834EPSS
SaveExploits0References2
Prion
Prion
•added 2018/02/15 10:29 a.m.•22 views

Hardcoded credentials

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...

6.8CVSS6.2AI score0.00834EPSS
SaveExploits0References2Affected Software1
Prion
Prion
•added 2018/02/15 10:29 a.m.•22 views

Improper access control

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

6.8CVSS8.1AI score0.01851EPSS
SaveExploits0References2Affected Software1
Prion
Prion
•added 2018/02/15 10:29 a.m.•23 views

Input validation

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

4.3CVSS6.3AI score0.00673EPSS
SaveExploits0References2Affected Software1
Prion
Prion
•added 2018/02/15 10:29 a.m.•28 views

Hardcoded credentials

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

6.8CVSS8AI score0.01323EPSS
SaveExploits0References2Affected Software1
NVD
NVD
•added 2018/02/15 10:29 a.m.•36 views

CVE-2017-12718

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on t...

8.1CVSS8.5AI score0.12785EPSS
SaveExploits4References4
NVD
NVD
•added 2018/02/15 10:29 a.m.•23 views

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

8.1CVSS8.2AI score0.01851EPSS
SaveExploits0References2
NVD
NVD
•added 2018/02/15 10:29 a.m.•25 views

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications...

4.3CVSS5.2AI score0.00975EPSS
SaveExploits0References2
NVD
NVD
•added 2018/02/15 10:29 a.m.•36 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.4AI score0.00673EPSS
SaveExploits0References2
NVD
NVD
•added 2018/02/15 10:29 a.m.•35 views

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

8.1CVSS8.1AI score0.01323EPSS
SaveExploits0References2
OSV
OSV
•added 2018/02/15 10:29 a.m.•14 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS5.8AI score0.00673EPSS
SaveExploits0References2
CVE
CVE
•added 2018/02/15 10:00 a.m.•84 views

CVE-2017-12722

CVE-2017-12722 affects Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump (versions 1.1, 1.5, 1.6). A DNS client in the MQX RTOS reads memory out-of-bounds, potentially crashing the communications module (remote exposure). Public docs consistently state this may be exploited remotely an...

5.3CVSS6.3AI score0.02415EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2018/02/15 10:00 a.m.•52 views

CVE-2017-12718

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on t...

8.4AI score0.12785EPSS
SaveExploits4References4
Cvelist
Cvelist
•added 2018/02/15 10:00 a.m.•38 views

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

8.2AI score0.01851EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2018/02/15 10:00 a.m.•32 views

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications...

4.2AI score0.00975EPSS
SaveExploits0References2