CVE
CVE
•added 2019/03/25 6:20 p.m.•66 views

CVE-2015-1012

The CVE-2015-1012 entry concerns the Hospira LifeCare PCA Infusion System. Vulnerabilities include cleartext storage of wireless network keys and hardcoded credentials, with multiple related issues (e.g., improper authorization, insufficient verification of data authenticity) that could enable un...

7.5CVSS7.5AI score0.00771EPSS
SaveExploits0References1Affected Software1
Prion
Prion
•added 2019/03/25 5:29 p.m.•23 views

Design/Logic Flaw

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira...

10CVSS7.3AI score0.02036EPSS
SaveExploits0References1Affected Software3
Prion
Prion
•added 2019/03/25 5:29 p.m.•32 views

Hardcoded credentials

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS6.9AI score0.01972EPSS
SaveExploits0References1Affected Software3
NVD
NVD
•added 2019/03/25 5:29 p.m.•41 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS9.5AI score0.01972EPSS
SaveExploits0References1
Prion
Prion
•added 2019/03/25 4:29 p.m.•29 views

Authorization

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

5CVSS6.6AI score0.01008EPSS
SaveExploits0References1Affected Software3
CVE
CVE
•added 2019/03/25 4:12 p.m.•73 views

CVE-2015-3954

Hospira Plum A+ Infusion System (versions 13.4 and earlier), Plum A+3 Infusion System (13.6 and earlier), and Symbiq Infusion System (3.13 and earlier) expose unauthenticated root privileges on Port 23/TELNET by default, allowing an unauthorized user to issue pump commands. Hospira notes Plum 360...

10CVSS9.5AI score0.02036EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2019/03/25 4:02 p.m.•65 views

CVE-2015-3953

CVE-2015-3953 affects Hospira Plum A+ Infusion System (versions prior to 13.4), Plum A+3 Infusion System (prior to 13.6), and Symbiq Infusion System (prior to 3.13). Root cause: hard-coded credentials allowing access via affected devices; additional risk factors include services listening on Port...

10CVSS9.2AI score0.01972EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/03/25 4:02 p.m.•40 views

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

9.5AI score0.01972EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/25 3:42 p.m.•71 views

CVE-2015-3952

Summary: CVE-2015-3952 concerns information disclosure from Hospira infusion systems where wireless keys are stored in plain text. Affected products: Plum A+ Infusion System v13.4 and earlier, Plum A+3 Infusion System v13.6 and earlier, and Symbiq Infusion System v3.13 and earlier. Root cause: cl...

7.5CVSS7.3AI score0.01008EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/25 12:00 a.m.•9 views

CVE-2015-1012: Cleartext Storage of Sensitive Information

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5CVSS5.8AI score0.00771EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/25 12:00 a.m.•8 views

CVE-2015-3952: Cleartext Storage of Sensitive Information

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

7.5CVSS5.7AI score0.01008EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/25 12:00 a.m.•6 views

CVE-2015-3954: Improper Authorization

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by default. An unauthorized user could issue commands to the pump. Hospira...

10CVSS5.8AI score0.02036EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/25 12:00 a.m.•10 views

CVE-2015-3953: Use of Hard-coded Password

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices...

10CVSS5.7AI score0.01972EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/25 12:00 a.m.•12 views

CVE-2015-3956: Insufficient Verification of Data Authenticity

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized configuration changes from unauthenticated devices on the host...

10CVSS5.7AI score0.00954EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2019/03/25 12:00 a.m.•6 views

PT-2019-7184

Name of the Vulnerable Software and Affected Versions Hospira Plum A+ Infusion System versions 13.4 and prior Hospira Plum A+3 Infusion System versions 13.6 and prior Hospira Symbiq Infusion System version 3.13 and prior Description The issue allows unauthorized devices on the host network to sen...

10CVSS0.00954EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/03/25 12:00 a.m.•8 views

PT-2019-7164

Name of the Vulnerable Software and Affected Versions Hospira LifeCare PCA Infusion System version 5 Description The issue concerns the storage of wireless keys in plain text. According to the information provided, version 3 of the system is not intended for wireless use and should not be modifie...

7.5CVSS0.00771EPSS
SaveExploits0References2
NVD
NVD
•added 2019/03/23 8:29 p.m.•33 views

CVE-2015-3965

Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated operations" by leveraging "elevated privileges" for an unspecified call to an incorrectly exposed function...

9CVSS8.5AI score0.02882EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/03/23 7:23 p.m.•37 views

CVE-2015-3965

Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated operations" by leveraging "elevated privileges" for an unspecified call to an incorrectly exposed function...

8.5AI score0.02882EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/23 7:23 p.m.•80 views

CVE-2015-3965

CVE-2015-3965 affects Hospira Symbiq Infusion System (Version 3.13 and earlier). The vulnerability arises from Exposed Dangerous Method or Function (CWE-749) that, with remote access and elevated privileges, could cause unanticipated operations on the device. Affected component is the device’s so...

9CVSS8.3AI score0.02882EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2019/03/23 12:00 a.m.•5 views

PT-2019-7185

Name of the Vulnerable Software and Affected Versions Hospira Symbiq Infusion System versions 3.13 and earlier Description The issue allows remote authenticated users to trigger unanticipated operations by leveraging elevated privileges for an unspecified call to an incorrectly exposed function...

9CVSS5.8AI score0.02882EPSS
SaveExploits0References2