103 matches found
K43877335: Intel software vulnerabilities CVE-2020-8751, CVE-2020-8755, CVE-2020-8761, CVE-2020-12303
Security Advisory Description CVE-2020-8751 Insufficient control flow management in subsystem for IntelR CSME versions before 11.8.80, IntelR TXE versions before 3.1.80 may allow an unauthenticated user to potentially enable information disclosure via physical access. CVE-2020-8755 Race condition...
CVE-2023-21444: Inadequate Encryption Strength
Improper cryptographic implementation in Samsung Flow for PC 4.9.14.0 allows adjacent attackers to decrypt encrypted messages or inject commands...
Siemens SINEC INS
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2021-40341: Inadequate Encryption Strength
DES cipher, which has inadequate encryption strength, is used Hitachi Energy FOXMAN-UN to encrypt user credentials used to access the Network Elements. Successful exploitation allows sensitive information to be decrypted easily. This issue affects FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B...
CVE-2022-24116: Inadequate Encryption Strength
Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0...
CVE-2022-45379: Inadequate Encryption Strength
Jenkins Script Security Plugin 1189.vbab7c8fd5fde and earlier stores whole-script approvals as the SHA-1 hash of the script, making it vulnerable to collision attacks...
Siemens SINEC INS
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Input Validation, Integer Overflow or Wraparound, Uncontrolled Resource Consumption, Command Injection, Inadequate Encryption Strength, Missing...
LS ELECTRIC PLC and XG5000 (Update A)
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor : LS ELECTRIC, LS Industrial Systems LSIS Co. Ltd Equipment: LS ELEC PLC and XG5000 Vulnerability: Inadequate Encryption Strength 2. UPDATE This updated advisory is a follow-up to the original advisory...
Inadequate Encryption Strength
Overview randompasswordgenerator is a generates a random password with various useful options. Affected versions of this package are vulnerable to Inadequate Encryption Strength due to the use of Kernelrand to generate passwords, which, as a result of its cyclic nature, can facilitate password...
Siemens RUGGEDCOM Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2022-24318
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...
CVE-2022-24318
CVE-2022-24318 affects ClearSCADA (All Versions) and EcoStruxure Geo SCADA Expert 2019/2020. The root cause is CWE-326: Inadequate Encryption Strength, causing non‑encrypted communication with the server when using outdated ViewX clients. The CVSS metrics updated show an attacker‑friendly network...
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Inadequate Encryption Strength (CVE-2018-4839)
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
VulnCheck KEV: CVE-2018-15811
DNN aka DotNetNuke 9.2 through 9.2.1 uses a weak encryption algorithm to protect input parameters...
CVE-2021-21387 Partial secret key disclosure, improper safety number calculation, & inadequate encryption strength
Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connectio...
CVE-2020-7565
CVE-2020-7565 affects Schneider Electric Modicon M221 PLCs (all versions) and is about Inadequate Encryption Strength (CWE-326). The root cause is weakness in cryptographic protection that could allow an attacker to break the encryption key when intercepting traffic between EcoStruxure Machine - ...
PT-2020-6348
Name of the Vulnerable Software and Affected Versions Modicon M221 all versions Modicon M100 affected versions not specified Modicon M200 affected versions not specified Description A CWE-326: Inadequate Encryption Strength issue exists that could allow an attacker to break the encryption key whe...
CVE-2020-13785
D-Link DIR-865L Ax 1.20B01 Beta devices have Inadequate Encryption Strength...
VISAM Automation Base (VBASE) (Update B)
1. EXECUTIVE SUMMARY CVSS v3 9.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: VISAM Equipment: VBASE Vulnerabilities: Relative Path Traversal, Incorrect Default Permissions, Inadequate Encryption Strength, Insecure Storage of Sensitive Information, Stack-based Buffer Overflow...
Rockwellautomation 1763-l16awa Inadequate Encryption Strength
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version...